Yodify Product Library
Instantly add the LE Series 1 m Range Laser Displacement Sensor and 50,000+ more product series to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

LE Series 1 m Range Laser Displacement Sensor

Brand: Banner Engineering

The LE series linear array technology provides great performance and resolution regardless of detection objects color or sheen.
Features
  • Ready to measure right out of the box.
  • Easy adjustment with a two-line, eight-character intuitive display.
  • Linear array provides repeatability and accuracy for challenging targets.
  • Visible laser for small spot size and easy alignment.
  • Models with IO-Link available.

1 - 12 of 56 Part Numbers
LE250D
LE250D
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 2 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250D W/30
LE250D W/30
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 9 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DC1
LE250DC1
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 2 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DC1 W/30
LE250DC1 W/30
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 9 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DC1Q
LE250DC1Q
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Integral QD
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - M12 (Euro) requires mating cordset
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DC1QP
LE250DC1QP
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Pigtail QD
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - M12 (Euro) requires mating cordset
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DQ
LE250DQ
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Integral QD
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - M12 (Euro) requires mating cordset
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250DQP
LE250DQP
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Pigtail QD
  • Delay at Power-up (ms) - 1000
  • Discrete (Switched) Outputs - 2 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - M12 (Euro) requires mating cordset
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250I
LE250I
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
  • Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
  • Analog Output Configuration - 4-20 mA
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 2000
  • Discrete (Switched) Outputs - 1 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Analog & Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 2 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250I W/30
LE250I W/30
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
  • Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
  • Analog Output Configuration - 4-20 mA
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 2000
  • Discrete (Switched) Outputs - 1 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Analog & Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 2
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 10000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 9 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250IC1
LE250IC1
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
  • Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
  • Analog Output Configuration - 4-20 mA
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 2000
  • Discrete (Switched) Outputs - 1 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Analog & Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 2 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
LE250IC1 W/30
LE250IC1 W/30
  • Adjustments - Push Button; Remote Teach
  • Alarm Output (mA) - 100
  • Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
  • Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
  • Analog Output Configuration - 4-20 mA
  • Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
  • Connection - Cable
  • Delay at Power-up (ms) - 2000
  • Discrete (Switched) Outputs - 1 NPN/PNP Configurable
  • Discrete Output Hysteresis (mm) - Automatically adjusted
  • Feature: Chemical Resistant - No
  • Feature: Health/ Marginal Signal Output - Yes
  • Feature: Remote Teach - Yes
  • Feature: Timing (Hold/Delay) - Yes
  • Housing Style - Rectangular
  • Indicator - LCD; LED(s)
  • Input/output - Analog & Discrete
  • IO Link - No
  • IP Rating - IP67
  • Laser Classification - Class 1
  • Laser Control - Yes
  • Max Ambient Light (Lux) - 5000
  • Max Discrete (Switched) Output (mA) - 100
  • Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
  • Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
  • Max Operating Temperature (°C) - 55
  • Max Sensing Distance (mm) - 400
  • Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
  • Min Operating Temperature (°C) - -20
  • Minimum Response Time (ms) - 2
  • Minimum Sensing Distance (mm) - 100
  • Minimum Window Size (mm) - 1
  • NEMA Rating - NEMA 6
  • Number of Pins - 5
  • Output Protection - Protected against continuous overload and short circuit
  • Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
  • Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
  • Power Supply - 12-30 V dc
  • Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
  • Primary Housing Material - Zinc Alloy Die-Cast
  • QD Type/Cable Length - 9 m
  • Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
  • Sensing Beam - Visible Red Laser
  • Sensing Beam Wavelength (nm) - 650
  • Sensing Mode (Detailed) - Triangulation
  • Sensing Mode (General) - Proximity
  • Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
  • Storage Temperature (°C) - -30 to 65
  • Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
  • Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
  • Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
  • Warm-up Time (minutes) - 10
  • Window Material - Acrylic
  • Wireless - No
1 - 12 of 56 Part Numbers
Instantly populate your store or catalogĀ 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more