Yodify Product Library
Instantly add the LE Series 1 m Range Laser Displacement Sensor and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
LE Series 1 m Range Laser Displacement Sensor
Brand: Banner EngineeringThe LE series linear array technology provides great performance and resolution regardless of detection objects color or sheen.
Features- Ready to measure right out of the box.
- Easy adjustment with a two-line, eight-character intuitive display.
- Linear array provides repeatability and accuracy for challenging targets.
- Visible laser for small spot size and easy alignment.
- Models with IO-Link available.
1 - 12 of 56 Part Numbers
LE250D
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250D W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DC1
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DC1 W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DC1Q
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Integral QD
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DC1QP
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Pigtail QD
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DQ
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Integral QD
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250DQP
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Pigtail QD
- Delay at Power-up (ms) - 1000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250I
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250I W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 10000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250IC1
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
LE250IC1 W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - LCD; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 1
- Laser Control - Yes
- Max Ambient Light (Lux) - 5000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 400
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 2
- Minimum Sensing Distance (mm) - 100
- Minimum Window Size (mm) - 1
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6 V at 100 mA
- Output Saturation Voltage PNP Outputs - < 3 V at 100 mA
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - 70 mA @ 24 V dc
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Remote Teach and Laser Control Input Impedence - 18 kΩ min. (65 kΩ min at 5 V dc)
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 650
- Sensing Mode (Detailed) - Triangulation
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 0.9 mm x 1.2 mm @ 400 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - +/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 10
- Window Material - Acrylic
- Wireless - No
1 - 12 of 56 Part Numbers
Documentation
Data Sheets
Product Manuals
- Banner Engineering LE Series 1 m Range Laser Displacement Sensor Product Manuals pdf 3.6 MB
- L GAGE LE250 550 Analog Discrete Laser Gauging Sensors Instruction Manual pdf 3.7 MB
- L GAGE LE250 550 Dual Discrete Laser Gauging Sensors Instruction Manual pdf 3.6 MB
- L GAGE LE250 550 Laser Gauging Sensor with IO Link Instruction Manual pdf 4.8 MB