Yodify Product Library
Instantly add the Model F3301/F33C1 Shear Beam Load Cell and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Model F3301/F33C1 Shear Beam Load Cell

Brand: Tecsis

The Models F3301 and F33C1 shear beam load cells are offered as an OEM alternative to our standard bonded-foil strain gage product line. 

The thin film technology featured in the F33 series provides outstanding performance, low power consumption, excellent stability and low temperature effects.
Features
  • Thin film technology (instead of conventional bonded foil strain gauges)
  • Corrosion free stainless steel
  • Integrated amplifier
  • Stable with changes in temperature
  • High long term stability
  • High shock and vibration resistance
  • For dynamic or static measurements
  • Good repeatability
  • Ease of installation
  • Available with ATEX approval

1 - 3 of 3 Part Numbers
F3301
F3301
  • Approval / Protection - Standard
F33C1 ATEX/IECEX
F33C1 ATEX/IECEX
  • Approval / Protection - ATEX/IECEX for II 2G Ex ib IIC T4/T3
F33C1 SIL-3
F33C1 SIL-3
  • Approval / Protection - SIL-3 Approval with 2-Channel PC Control
1 - 3 of 3 Part Numbers

Specifications

Brand

Accuracy

  • 0.5%

Approvals & Certifications

  • EN 61326
  • ISO 9001: 2015 Certified
  • SIL 3 Certification

Approvals & Certifications

  • ATEX Ex II 2 G Ex Ib IIC T4/T3
  • CSA
  • EMC According to Directive EN 61326
  • FM
  • IEC Ex
  • TÜV-Sud- No. Z-IS-ATA3-MAN 6000219499 According to EN 62061: 2005
  • UL

Channels

  • 2

Consumption

  • Power Consumption: Approximatelyimatly 100 mW, 8 ± 0.2 mA Respectively 5 ± 0.2 V - F33C1 SIL 3

Electrical Connectors

  • Circular Connector 4-Pin M12 x 1 - F3301, F33C1-ATEX-/ IECEX

Electrical Protection

  • Overvoltage
  • Reverse Polarity
  • Short Circuit Protected

Environmental Protection

  • Protection Typical (According to EN 60 529 / IEC 529): IP67

Hysteresis

  • ≤ ± 0.2 % of Full Scale Cn

Insulation Resistance

  • > 5 GigaOhms / 50 V

Load Limit

  • Breaking Force: > 300 % Fnom
  • Limit Force: 150 % Fnom

Materials of Construction

  • Material of Measuring Device: Stainless Steel

Measuring Error

  • Combined Error: ≤ ± 0.5 % of Full Scale

Measuring Range

  • 2 to 100 KN

Output

  • Analog Output: 0-10 Vdc, 3-Wire - F3301, F33C1-ATEX-/ IECEX
  • Analog Output: 4-20 mA, 2-Wire - F3301, F33C1-ATEX-/ IECEX
  • Approximately 8 mA - F3301, F33C1-ATEX-/ IECEX

Power Requirement

  • 10-30 Vdc for Current Output - F3301, F33C1-ATEX-/ IECEX
  • 14-30 Vdc for Voltage Output - F3301, F33C1-ATEX-/ IECEX1

Power Supply

  • 24 V, Max.

Response Time

  • ≤ 1 millisecond (within 10 to 90 %) - F3301, F33C1-ATEX-/ IECEX
  • ≤ 5 milliseconds (within 10 to 90 %)

Sensitivity

  • Cross Sensitivity (Signal with 100 % Fnom at 90°): < 5 % of Full Scale

Service Temperature

  • -40° to 80° C (-40° to 176° F)

Span & Zero Effect

  • ≤ ± 0.2 % of Full Scale/10K

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Temperature Range

  • Nominal -20° to 80° C (-4° to 176° F)

Vibration

  • Vibration Resistance: 20 G (50 to 150 Hz) (According to DIN EN 60068-2-6)

  • Automated Manufacturing
  • Chemical & Petrochemical
  • Dedusting & Filtration Units
  • Industrial Weighing
  • Mechanical Engineering & Machinery
  • Mining
  • OEM Applications
  • Torque Support