Yodify Product Library
Add the RT721 Programmable RTD Temperature Transmitter to your store or catalog  
Book Your Demo and See How
or create your store

RT721 Programmable RTD Temperature Transmitter

Brand: Intempco Controls, Inc

The RT721 is a low cost three-wire transmitter that converts a Pt100 ohm input to proportional voltage signal. 

The transmitter provides sensor excitation and includes linearization, lead wire compensation, and lead-break detection functions. 

Setup and calibration are made with a USB connection to your PC and Intempco’s configuration software. 

Advanced signal processing capabilities and variable range input make this instrument very suitable for the most demanding temperature measurement applications.
Features
  • Easy setup, digital calibration and fully field re-programmable via USB module and PC Windows based software
  • Factory calibrated or customer calibrated
  • 0-1 Vdc, 0-5 Vdc, 1-5 Vdc or 0-10 Vdc output
  • High accuracy and linearity Input 100 ohm Pt RTD (385 alpha) with 3-wire compensation
  • Low temperature drift and wide ambient temperature range
  • Metal housing mounts in DIN form B sensor heads

1 - 1 of 1 Part Numbers
RT721
RT721
  • Output - 0-1 Vdc
  • Temperature Range - °F Ranges
1 - 1 of 1 Part Numbers

Specifications

Accuracy

  • ± (0.05° C (0.09° F) + 0.05 % of Calibrated Span) or Better with Two-Point Calibration with Sensor
  • ± 0.10 % of Span (Includes the Effects of Linearization & Repeatability, But Not Include Sensor Error)

Adjustment Type

  • Factory Set (Pre-Set) or Customer Calibrated

Communication

  • USB

Current

  • Excitation Current RTD: 0.2 mA

Enclosure Finish

  • Enamel Painted

Enclosure, Body Material

  • Die Cast Zinc

Mounting

  • DIN Rail (DIN 46277)

Operating Temperature

  • -40° to 80° C (-40° to 176° F)

Output

  • 0-1 Vdc
  • 0-10 Vdc
  • 0-5 Vdc
  • 10 mA - Max.
  • 1-5 Vdc

Power Supply

  • 12-32 Vdc, Polarity Protected

Power Supply Effect

  • < 0.001 %/V

Resistance

  • Sensor Lead Resistance RTD: RTD Resistance + 2 x lead wire resistance must be less than 4 kΩ

Resolution

  • Output Resolution: 0.16 mV (15-bit)

RFI/EMI Effect

  • 1 % or Less Typical

RTD Type

  • Pt100, 3-Wire, Alpha = 0.00385, DIN EN 60751

Sensor, Probe Connection

  • 3-Wire

Sensor, Probe Type

  • RTD

Span - Minimum

  • 50° C (122° F)

Span & Zero Adjustments

  • By Software

Stability

  • Long Term Drift: ≤ 0.1 % of Full Scale Per Year

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Temperature Effect

  • ± 0.002° C/°C

Temperature Range

  • Software Re-Scalable between -200° to 600° C (-328° to 1,112° F)

Update Time

  • Warm-Up: 30 seconds

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more