Yodify Product Library
Instantly add the FLT93C FlexSwitch Sanitary Insertion for Flow, Level & Temperature and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
FLT93C FlexSwitch Sanitary Insertion for Flow, Level & Temperature
Brand: Fluid Components International LLC (FCI)Delivering the same field-tested performance and reliability as the FLT93 S and F, the FLT93 C is built with 316L stainless steel wetted parts that are electro-polished to 20 Ra, and the process connection is a sanitary flange to meet the sanitary requirements of the food, beverage, pharmaceutical and chemical industries.
The instrument’s no moving parts design makes it ideal for monitoring the flow of syrups, fillings and other viscous media and product slurries. The FLT93 C is suitable for both clean-in-place and steam-in-place applications.
Features- Temperature compensation
- Analog output voltage for flow and temperature
- Calibration mode switch to simulate alarm setpoint
- Fail-safe setup
- Dual alarm, each with SPDT relay (DPDT optional)
- Field selected input power
Specifications
Accuracy
- Factory Calibrated Switch Point Accuracy: ± 2 % of Set Point Velocity over an Operating Temperature Range ± 28° C (± 50° F)
- Field Set Point Adjustment (Temperature Service): ± 1° C (± 2° F)
- Monitoring Accuracy: ± 5 % of Reading or ± 0.04 sfps (± 0.012 NMPS) for Liquids or ± 2 sfps (± 0.61 NMPS) for Gas, whichever is Larger
- Standard Curve Fit Output Voltage Operation Across the Selected Instrument Temperature Range: ± 2° C (± 3.5° F)
Adjustment Type
- Factory Set (Pre-Set)
- Field Adjustable
Applications
- Additive Verification
- Analyzer & Syrup Flow Monitoring
- Gas/Steam Injection Monitoring
- Level/Interface
- Low Flow Detection
- Pump Protection
Approvals & Certifications
- SIL: SIL 2 Compliant, Safe Failure Fraction (SFF) 82 to 84 %
- ISO 9001
- AS 9100
- ATEX: II 2 G Ex d IIC T6 to T2 -40° to 60° C Gb, II 2 D Ex TD A21 IP66 T85° to T355° C
- CE
- EAC TR CU
- IECEx: Ex d IIC T6 or T5
- INMETRO
- LVD
- PED
- RoHS
Cable Length
- 10 to 50 feet (3 to 15 metres)
Cable Material
- PVC: 90° C (190° F)
- Teflon: 150° C (300° F)
Conduit Connection
- 1/2” NPT Female
- 3/4” NPT Female
Electrical Contacts
- Gold-Plated
Electrical Rating
- Dual Hermetically Sealed Relays, MIL-SPEC Grade: 0.5 A at 115 Vac Resistive
- Dual Hermetically Sealed Relays, MIL-SPEC Grade: 2 A at 28 Vdc
- Dual SPDT or Single DPDT, Field Configurable: 6 A Resistive at 115/240 Vac (Gold-Plated Contacts)
- Dual SPDT or Single DPDT, Field Configurable: 6 A Resistive at 24 Vdc (Gold-Plated Contacts)
Enclosure Finish
- Aluminum: Polyester Painted
Enclosure, Body Material
- 316 Stainless Steel
- Aluminum
Environmental Protection
- IP66
- IP67
- NEMA 4X
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - Unrated
Flange Size - 1” (DN 25)
- 1” (DN 25) - Unrated
Flange Size - 2” (DN 50)
- 2” (DN 50) - Unrated
Flange Size - 3/4” (DN 20)
- 3/4” (DN 20) - Unrated
Input Power
- 108-132 Vac at 13 W, 100 mA - Max.
- 18-28 Vdc at 7 W, 230 mA - Max.
- 207-240 Vac at 14 W, 50 mA - Max.
- 21-30 Vdc at 7 W, 230 mA - Max.
Insertion 'U' Length
- 1.17 to 2.75”
Media
- Gas
- Liquids
Mounting
- Panel Mounted Control Circuit
Name Plate, Tag Material
- Mylar
- Stainless Steel
Operating Temperature
- -40° to 60° C (-40° to 140° F)
Pressure Range
- psig: 0 to 6,000 (kPa: 0 to 41,370, bar: 0 to 414)
Process Temperature
- -73° to 260° C (-100° to 500° F)
Repeatability
- Flow Service: ± 0.5 % of Reading
- Temperature Service: ± 0.6° C (± 1.0° F)
Switch Point Range
- Air/Gas: 0.25 to 120 sfps (0.08 to 36.6 NMPS)
- Syrup: 0.01 to 5 sfps (0.003 to 1.5 mps)
- Water: 0.01 to 10 sfps (0.003 to 3 mps)
Switch Type
- DPDT
- Hermetically Sealed
- SPDT
Temperature Range
- -40° to 177° C (-40° to 350° F)
Wetted Materials
- 316L Stainless Steel with All-Welded Construction Electro-Polished to 20 Ra
- Interface and Sump Level Detection
- Interface / Sump Level Detection in Separation Vessels
- Agitation Detection
- Interface / Level Detection in Settling Vessels
- Foam or Sediment Level Control
- Liquid/resin Interface Detection