mA-Isolating Repeater Series 9164 - Non Ex i
Brand: R. STAHL AGThe mA - isolating repeaters are used for connection of 4-wire transmitters to active 2-wire inputs (source) as well as to galvanic isolation. The devices bidirectionally transfer a superimposed HART communications signal.
Features- Interconnection of two mA-sources and active 2-wire inputs is possible
- Ideal solution for integrating 4-conductor measuring transmitters into analogue input supplies.
- Bidirectional HART transmission 4 ... 20 mA
- Galvanic isolation between input and output
1 - 1 of 1 Part Numbers
224366
Interconnection of two mA-sources and active 2-wire inputs is possible
Ideal solution for integrating 4-conductor measuring transmitters into analogue input supplies.
Bidirectional HART transmission 4 ... 20 mA
Galvanic isolation between input and output
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Relative humidity max. - ≤ 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Auxiliary power nom. voltage - 30 V
- Nominal current - 30.00 mA
- Polarity reversal protection - yes
- Power dissipation max. - 3.7 V x 20 mA + 20 mA x
- Power dissipation max. 2 - (supply voltage - RL x 20 mA)
Electrical Data
- communication signal - HART, 0.5 ... 5 kHz
- Isolating repeater mode - Yes
- Number of channels - 1
- Transmitter supply mode - No
Explosion Protection
- Application range (zones) - 2
- ATEX dust certificate - BVS 15 ATEX E 068 X
- ATEX gas certificate - R. STAHL Test Report 11006
- Certificates - Canada (FM), SIL (exida), USA (FM)
- Gas explosion protection ATEX - II 3 G Ex ec IIC T4 Gc
- Installation in Division NEC 500 - (Class I) 2
Galvanic isolation
- Galvanic isolation Ex i to Ex i - 500 V AC
General
- Functional Description - The mA - isolating repeaters are used for connection of 4-wire transmitters to active 2-wire inputs (source) as well as to galvanic isolation. The devices bidirectionally transfer a superimposed HART communications signal.
- Highlights - Interconnection of two mA-sources and active 2-wire inputs is possible Ideal solution for integrating 4-conductor measuring transmitters into analogue input supplies. Bidirectional HART transmission 4 ... 20 mA Galvanic isolation between input and output
- Product Description - mA isolating repeater Non-Ex i field circuit
- Product Type - 9164/13-20-55
- Title Product Variant Technical Data - 9164/13-20-55 mA-isolating repeat. nEx i
- WebCode - 9164B
Input
- Active supply voltage range - 5 - 30 V
- Input - 4 ... 20 mA HART (sink)
- Input function - Isolation amplifier
- Input functional range - 3,6 - 25 mA
- Input resistance - > 10 kΩs
- input signal - 3,8 ... 20,5 mA with HART
- voltage drop - < 3,7 V
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Grid dimension - 12.00 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.090 kg
Mounting / Installation
- Conduct cross-section flexible max. - 1.5 mm²
- Conduct cross-section flexible max. - 0.2 mm²
- Conductor cross-section solid max. - 1.5 mm²
- Conductor cross-section solid min. - 0.2 mm²
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- Behaviour of the output - = input signal
- deviation - ≤ 0,1 %
- LFD relay - No
- linearity error - ≤ 0,05 %
- offset error - ≤ 0,05 %
- Output - passive HART (sink)
- Output current at I e =0 - 0 mA
- output signal - 3.8 - 20.5 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0,05 % / 10K