Brand: Goulds Water TechnologyA variable speed pump controller made specifically for single pump booster applications. Comes complete with pressure transducer and standard NEMA 3R outdoor rated enclosure.
Features- Easy Set-up: Pre-set for surface motor characteristics. Pre-wired and tested transducer. Touch button pressure setting. No complicated menus or electrical jargon to cope with. Total set up time including wiring is less than 30 minutes.
- NEMA 3R: Outdoor rated enclosure eliminates the need for separate cover panels required by standard NEMA 1 enclosures.
- Dual Phase: The same drive can be used for either three phase or single phase input (de-rated). Both configurations are UL/CUL approved for inventory flexibility.
- Transducer: As with all Goulds Water Technology drives, the pressure transducer is included with the drive so there is no need for separate sourcing and compatibility checks. The transducer is pre-wired and tested.
- Full Diagnostics: In addition to typical electrical protection and diagnostics, the S-Drive has a full range of pump protection features such as bound pump or motor shut down, low water or loss of prime shut down. These added features require no added input devices.
- Program Security: The flashing LED status indicator will not fade in outdoor use the way LCD screens do, and the internal single push button discourages tampering by untrained operating or maintenance personnel.
- Remote on/off: Permits external control by timers (irrigation), float or pressure switches (tank draining) or manual control. Reduces the need for separate patch panels.
- Hand/Auto Option: Allows the drive to be run full speed for longer periods of time as in the case of system start up. Turning the control back to auto resumes the automatic pressure tracking and control.
- Remote Monitoring: External monitors may be connected to the drive for pump running speed (Hz), pump on, and system fault. The fault indicator can also be connected to devices like an auto-dialer. This enables control of pumps and drives in un-manned locations.
- Dual Set Point: The S-Drive has the capability to be programmed with two pressure set points. An external contact such as a timer can be used to change between them, so that a booster pump serving both a building and an irrigation system can do both jobs without manual resets.
Specifications
Brand
Motor Overload Setting
- May be set from 40-100%
Minimum Speed
- 15 Hz and 30 Hz minimum frequency settings. (Permanently set to 30 Hz on filtered product.)
Carrier Frequency
- 2 KHz to 8 KHz (Permanently set to 2 KHz on filtered product.)
Ramp Setting
- Adjust acceleration and deceleration ramps from .5 to 7 seconds
No Water Restart Time
- Restart delay after ddry well or loss of prime fault adjustable from 10 minutes to 2 hours.
- Water pumps serving commercial buildings
- Pressure boosting for light industry, wash systems, filtration
- Rural water and municipal systems
- Groundwater/Irrigation
Documentation
Brochure
- Commercial Products - Pumps • Controls • Pressure Boosting (BRGLCAR R6) pdf 3.3 MB
- Gamme de produits à vitesse variable (fr) (BRCPVFDFR R7) - DISCONTINUED pdf 11.8 MB
- Línea de Productos de Velocidad Variable (sp) (BRCPVFDSP R7) - DISCONTINUED pdf 11.8 MB
- Productos Comerciales – Bombas • Controles • Aumento de Presión (BRGLCARSP R5) (Español) pdf 10.7 MB
- Produits commerciaux - Pompes • Contrôleurs et Commandes • Surpression (BRGLCARFR R5) pdf 10.7 MB
- Variable Speed Product Line Brochure (BRCPVFD R8) pdf 13.0 MB
Manual
- 9K585 Moisture Sensor Relay Installation and Operation Instructions (IM234R03) pdf 3.3 MB
- Aquavar SPD Above-Ground Quick Start Up Guide (IMS-SPDQ-1) pdf 46 KB
- S-Drive Constant Pressure Aquavar SPD Variable Speed Pump Control (IM213R07) pdf 3.2 MB
- S-Drive Quick Start Up Guide (IM216R03) pdf 157 KB
- S-Drive Quick Start Up Guide (IMS-SDQ-1) pdf 101 KB
- S-Drive Quick Start Up Guide (IMS-SDQ-2) pdf 194 KB
- VFD Quick Start Safety Guidelines (IMS-HAZARD-1) pdf 99 KB