Yodify Product Library
Instantly add the CamCor CT Coriolis Flow Meter & Transmitter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

CamCor CT Coriolis Flow Meter & Transmitter

Brand: Cameron

Equipped with a sophisticated transmitter (including extensive diagnostics, a large display, and field configurability via keypad), the Cameron CT Series are high-performance Coriolis flow meters capable of mass flow measurement with a high degree of accuracy.

Particularly worth noting are its uses in non-routine flow rate measurement, including measurement of extra low-volume flows, short-duration filling processes, etc.
Features
  • Outstanding zero stability performance
  • High-accuracy density: ±0.0005 g/mL (Models CC003 to CC250)
  • Fast response and calculation frequency
  • Dual independent pulse outputs, dual independent
  • Analog outputs, one status input and one status output
  • Configurable via keypad or digital communications
  • Extensive self-diagnostic capabilities (connection faults, pipeline vibration, media pulsation, etc.)
  • Enhanced maintenance functions (event/user change logging and downloads, recoverable factory configuration and calibration, etc.)
  • User-configurable alarms Compatible with HART and Modbus communication protocols

Specifications

Brand

Accuracy

  • High-Accuracy Density: ± 0.0005 G/mL

Ambient Temperature Range

  • -40°C to 55°C (-40°F to 131°F)

Approvals & Certifications

  • ATEX: 94/9/EC, EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012
  • CSA: Class I, Zone 1, Ex d Ib IIB T4 Gb, Class I, Zone 1, Ex d [ib] IIB T6 Gb
  • EMC Directive: 2004/108/EC, EN 55011: 1998, A1, 1999, A2: 2002, Group 1, Class B, EN 61000-6-2: 2001, EN061326-1: 2006
  • IEC Ex: IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC 60079-11: 2011

Communication

  • HART
  • Modbus

Conduit Connection

  • ¾” NPT Female

Configuration

  • Integral - Transmitter
  • Separately Mounted - Transmitter

Consumption

  • Maximum

Damping Adjustment

  • Density: 4 seconds
  • Flow Rate: 0.8 second
  • Temperature: 2.5 seconds

Density Range

  • 0.3 to 2 G/mL - Metering Range (Liquid)

Display

  • 128 x 64 Dots LCD
  • Backlit
  • LCD & LED

Electrical Connectors

  • Minimum Conductor Size: 18 AWG

Enclosure Finish

  • Paint Color: Light Gray (RAL7035)
  • Paint Typical: Baked Enamel

Enclosure, Body Material

  • 304 Stainless Steel

Environmental Protection

  • IP66
  • IP67

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ASME
  • 1” (DN 25) - 300# ASME
  • 1” (DN 25) - 600# ASME
  • 1” (DN 25) - 900# ASME
  • 1” (DN 25) - PN 10
  • 1” (DN 25) - PN 16
  • 1” (DN 25) - PN 25
  • 1” (DN 25) - PN 40

Flange Size - ½” (DN 15)

  • ½” (DN 15) - 150# ASME
  • ½” (DN 15) - 300# ASME
  • ½” (DN 15) - 600# ASME
  • ½” (DN 15) - 900# ASME
  • ½” (DN 15) - PN 16
  • ½” (DN 15) - PN 25
  • ½” (DN 15) - PN 40
  • ½” (DN 15) - PN 10

Flange Size - 10” (DN 250)

  • 10” (DN 250) - 150# ASME
  • 10” (DN 250) - 300# ASME
  • 10” (DN 250) - 600# ASME
  • 10” (DN 250) - PN 10
  • 10” (DN 250) - PN 16
  • 10” (DN 250) - PN 25
  • 10” (DN 250) - PN 40

Flange Size - 1½” (DN 40)

  • 1½” (DN 40) - 150# ASME
  • 1½” (DN 40) - 300# ASME
  • 1½” (DN 40) - 600# ASME
  • 1½” (DN 40) - 900# ASME
  • 1½” (DN 40) - PN 10
  • 1½” (DN 40) - PN 16
  • 1½” (DN 40) - PN 25
  • 1½” (DN 40) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ASME
  • 2” (DN 50) - 300# ASME
  • 2” (DN 50) - 600# ASME
  • 2” (DN 50) - 900# ASME
  • 2” (DN 50) - PN 10
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 25
  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# ASME
  • 3” (DN 80) - 300# ASME
  • 3” (DN 80) - 600# ASME
  • 3” (DN 80) - 900# ASME
  • 3” (DN 80) - PN 10
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 25
  • 3” (DN 80) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 300# ASME
  • 4” (DN 100) - 600# ASME
  • 4” (DN 100) - PN 10
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 25
  • 4” (DN 100) - PN 40
  • 4” (DN 100) 150# ASME

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150# ASME
  • 6” (DN 150) - 300# ASME
  • 6” (DN 150) - 600# ASME
  • 6” (DN 150) - PN 10
  • 6” (DN 150) - PN 16
  • 6” (DN 150) - PN 25
  • 6” (DN 150) - PN 40

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150# ASME
  • 8” (DN 200) - 300# ASME
  • 8” (DN 200) - 600# ASME
  • 8” (DN 200) - PN 10
  • 8” (DN 200) - PN 16
  • 8” (DN 200) - PN 25
  • 8” (DN 200) - PN 40

Flange Type

  • Raised Face (RF)

Flow Rate

  • 0.00088 to 514 lbs/min - Guaranteed Minimum Mass Flow Rate
  • 0.0044 to 2572 lbs/min - Minimum Setting of Mass Flow Rate
  • 0.088 to 51441 lbs/min - Maximum
  • 0.132 to 102883 lbs/min - Maximum

Media

  • Gas
  • Liquids

Mounting Position

  • Horizontal Piping
  • Vertical Piping

NPT Connection

  • ½” NPT Female
  • ¼” NPT Female
  • ¾” NPT Female

O-Ring Material

  • Fluoroelastomer
  • PTFE
  • Viton

Operating Pressure

  • psi: 142 (kPa: 979, bar: 9.79) - Maximum
  • psi: 2,176 (kPa: 15,000, bar: 150) - Maximum

Output

  • 10-30 V, 50 mA DC - Open Collector Pulse Output
  • 4-20 mA DC, Maximum

Output Format

  • Pulse Output

Output Impedence

  • 2.2 kiloohms - Pulse Output

Power Supply

  • 20-30 Vdc
  • 85-264 Vac, 50/60 Hz

Pressure Range

  • psig: 203 to 1,044 (kPa: 1,400 to 7,198, bar: 14 to 71.98) - Sensor Housing Withstand

Range

  • Transmission Length of Separately-Mounted: 656 feet (200 metres)
  • Transmission Length: up to 3937 feet (1,200 metres) at 100 Hz

Repeatability

  • ± 0.05 % of Reading ( ±½ ZS) at Liquids
  • ± 0.1 % of Reading ( ±½ ZS) at Liquids
  • ± 0.25 % of Reading ( ±½ ZS) at Gases

Resistance

  • Pulse Ouput ON Resistance: ≤ 0.6 ohm
  • Status Output ON Resistance: ≥ 0.6 ohm

Response Time

  • 25 to 50 milliseconds

Rotation

  • Bi-Directional - Flow Direction

Stability

  • 0.000013 to 2.572 lbs/min - Zero Stability

Temperature Range

  • -200°C to 200°C (-328°F to 392°F)

Tri-Clamp Connection

  • 1” IDF Ferrule
  • ½” IDF Ferrule
  • 1½” IDF Ferrule
  • 2” IDF Ferrule
  • 3” IDF Ferrule

Uncertainty

  • ± 0.003 G/mL - Uncertainty of Density (Liquid)
  • ± 0.1 % of Full Scale - Analog Output Uncertainty
  • ± 0.2 % of Reading ( ± Zero Stability) - Uncertainty of Flow Rate (Liquid)
  • ± 0.5 % of Reading ( ± Zero Stability) - Uncertainty of Flow Rate (Gas)

Wetted Materials

  • 316L Stainless Steel
  • Alloy C-22 (Hastelloy)
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more