Yodify Product Library
Add the GD10P-CO₂ IR Point Gas Detector to your store or catalog
Book Your Demo and See How
or create your store
GD10P-CO₂ IR Point Gas Detector
Brand: Detcon IncThe GD10P-CO₂ uses state of the art IR gas measurement to give a fast, reliable response.
The GD10P has set the standard for gas detection in the areas of safety, stability and low maintenance.
The GD10P-CO₂ has been designed with features that provide an effective response to the detection of CO₂ in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.
The GD10P-CO₂ differs from all other point infrared gas detectors, because it utilizes silicon based solid-state sources.
The complete optomechanical design and constructions is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
Supplied with worldwide hazardous area approvals. Suitable for use in SIL 2 systems.
An industry standard HART interface is used for configuration of special fault levels as well as access to extended maintenance data.
Specifications
Brand
Accuracy
- ± 5 % of Full Scale between 0 to 50 % of Reading
- ± 7 % of Full Scale between 50 to 80 % of Reading
Approvals & Certifications
- ABS: #04-LD444057-PDA
- ATEX: 07-ATEX-1438
- CSA: 1773527
- IECEx: NEM 07.0006
- INMETRO: AEX-11698
- SIL 2
Cable Entry
- M20 EExe Cable Gland
Communication
- HART
Consumption
- 3.5 W - Approximately
Current
- 4-20 mA
Electrical Connectors
- 3-Wire (0.5 to 1.5 mm²)
Enclosure, Body Material
- 316 Stainless Steel - SIS2343
Environmental Protection
- IP66
- IP67
Frequency
- 50 Hz - Flash
Humidity
- 100 % RH
Load Impedance
- Maximum
Measuring Range
- 0 to 100 % by Volume
- 10,000 ppm
Media
- Gas - CO₂
Operating Temperature
- -20° to 65° C (-4° to 149° F)
Output
- 1 mA - Dirty Optics Dirt Accumulation
- 2 mA - Early Clean Optics Prewarning
- 4-20 mA - Standard
Response Time
- Start-Up Time: < 60 seconds
- T20 = 1 second (Configurable 0.3 second)
- T50 = 2.5 seconds (Configurable 0.7 second)
- T90 = 6 seconds (Configurable 1.6 seconds)
Stability
- ± 7 % of Full Scale Reading - Lifetime
Storage Temperature
- -40° to 70° C (-40° to 158° F)
Supply Voltage
- 18-32 Vdc - Range
- 24 Vdc