FN9620 Force Load Cell
Brand: American Sensor Technologies IncThe FN9620 is a S-Beam load cell with ranges from 500 N to 10 kN, designed to operate in hostile environments from -40 to 90° C with IP68 ingress protection.
It provides high stiffness for high cycle use, low off-axis load sensitivity and high level of accuracy. To ease its use for Process Control Automation equipment, the sensor’s sensitivity (in mV/V) is calibrated with 2% tolerance. On request, Instruction documents can be provided to ease the selection and use of our sensors and provide helpful tips.
Features- High Tensile Strength Stainless Steel
- Metric or Imperial thread
- Surcharge Sans Destruction 300%
- Safe Over Load 300%
- 3 meters Integral Cable
- IP68-1 meter water column
1 - 10 of 10 Part Numbers
FN9620-M-0.5KN
- Thread - M12 x 1.75-6H
- Standard Range - 0.5 kN
FN9620-M-10KN
- Thread - M12 x 1.75-6H
- Standard Range - 10 kN
FN9620-M-1KN
- Thread - M12 x 1.75-6H
- Standard Range - 1 kN
FN9620-M-2KN
- Thread - M12 x 1.75-6H
- Standard Range - 2 kN
FN9620-M-5KN
- Thread - M12 x 1.75-6H
- Standard Range - 5 kN
FN9620-X-0.5KN
- Thread - 1/2"-20 UNF-2B
- Standard Range - 0.5 kN
FN9620-X-10KN
- Thread - 1/2"-20 UNF-2B
- Standard Range - 10 kN
FN9620-X-1KN
- Thread - 1/2"-20 UNF-2B
- Standard Range - 1 kN
FN9620-X-2KN
- Thread - 1/2"-20 UNF-2B
- Standard Range - 2 kN
FN9620-X-5KN
- Thread - 1/2"-20 UNF-2B
- Standard Range - 5 kN
1 - 10 of 10 Part Numbers
Specifications
Applications
- Laboratory & Research
- Mechanical Resistance of Materials
- Process Control & Automation
- Structure Testing
- Test Benches
Approvals & Certifications
- CE
Cable Length
- 9.84 feet (3 metres)
Compensated Temperature
- -10° to 45° C (14° to 113° F)
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP68
Frequency
- 1 to 2.15 kHz - Natural Frequency
Hysteresis
- ± 0.03 % of Full Scale
Insulation Resistance
- > 5,000 megaohms - Insulation Under 50 Vdc
Linearization
- ± 0.05 % of Full Scale
Load Limit
- 100 % of Full Scale - Side Load Limit
Loop Resistance
- 340 to 450 ohms - Bridge Resistance Min./Max.
- 350 ohms - Bridge Resistance
Operating Temperature
- -40° to 90° C (-40° to 194° F)
Repeatability
- ± 0.02 %
Sensitivity
- 0.1 %/mm - Eccentric Load Sensitivity
- 1 % - Side Load Sensitivity
- 1-2 mV/V ± 2 % of Full Scale Output
Supply Voltage
- 10 Vdc
- 2-12 Vdc - Power Supply Min./Max.
Zero Balance
- ± 0.004 to 0.008 % of Full Scale/°C - Thermal Zero Shift
Zero Offset
- ± 2 % of Full Scale
- Structure Testing
- Test Benches
- Process Control & Automation
- Mechanical Resistance of Materials
- Laboratory and Research