Yodify Product Library
Add the 98 Series Spring Stainless Steel Nipple Union to your store or catalog
Book Your Demo and See How
or create your store
98 Series Spring Stainless Steel Nipple Union
Brand: International Metal Engineering (IME)The 98 series are ATEX and IECEx approved temperature assemblies. These temperature assemblies encompass our 8080KN Battery Operated Digital Temperature Indicator, 8080PR Indicating Temperature Temperature switch with Dual Relays, 8080PN Indicating Transmitter Transmitter and our 8080HT Indicating Temperature Transmitter with Hart.
Specifications
Accuracy
- 0.1 % of Calibrated Range ± 1-Digit for Model 8080PR, Model 8080PN
- Accuracy (Pt100): < 0.2K or 0.08 % for Model 8080HT
- Alarm Set Point Accuracy: ± 0.5 % of Full Scale for Model 8080PR
- Digital Accuracy: ± 0.1° C (± 0.18° F)
- Indication Accuracy: 0.5° C (0.9° F) for Model 8080KN
Adjustable Set Point Range
- 0 to 100 % of Full Scale for Model 8080PR
Alarm
- Overranging: Linear Rise to 20.8 mA
- Sensor Break, Sensor Open Circuit: < 3.8 mA
- Underranging: Linear Drop to 3.8 mA
Ambient Temperature Range
- -20° to 70° C (-4° to 158° F) with Display
- -40° to 85° C (-40° to 185° F) without Display
Approvals & Certifications
- ATEX
- CE
- Electromagnetic Compatibility (EMC): Interference Immunity & Interference Emission According to GB / T17626.2-1998), Compliance with IEC 61000-4-3: 1995
- Ex: II 2 GD, Exd IIC T6 Gb, Ex Tb IIIC T85° C Db, IP68 Ta = -40° to 70° C
- IECEx d IIC T6 Gb, Ex Tb IIIC T85° C Db, IP68 Ta = -40° to 70° C
Battery Life
- 24 Months for Model 8080KN
Burn-Out
- Burn-Out Protection: Upscale for Model 8080PN
Communication
- HART
Conduit Connection
- 1/2" BSP
- 1/2" NPT
- 3/4" NPT
- M20 x 1.5P
Delay Time
- Switch on Delay: ≤ 5 seconds
Display
- Multiple Backlight Rotatable LCD Display
Element
- Dual Elements
- Single Element
Environmental Protection
- IP68
Filter
- Filter Configuration: 0-160 μA
Indication
- Alarm Status Indication: LED on Front Panel for Model 8080PR
- Over Range Indication: Flash of Display for Model 8080PR
Isolation
- Galvanic Isolation: 2 kVac (In/Out) for Model 8080HT
Length
- N Length: 2 to 7" (50.8 to 177.8 mm)
Load Effect
- Supply & Load Effect: < 0.03 % of Span for Full Change for Model 8080PN
Output
- 2-Wire, 4-20 mA, Analog Output (with HART Protocol - Model 8080HT)
- Alarm Output: 2 Sets SPDT, 1 Form C, Rated 10 A at 250 Vac, 50/60 Hz for Model 8080PR
Override
- When the Input Falls Below the Alarm Set Point by Approximately Supply Voltage ± 0.5 % of Full Scale: Auto Reset
Resistance
- Resistance Transmitter: 0 to 10,000 ohms
Resistance Effect
- < ± 0.05 / 10 ohms Lead Resistance for Model 8080PN
Resolution
- 0.3 µA for Model 8080HT
Response Time
- 1 second
- Typically 75 ms for Model 8080PR
RTD Type
- Cu100
- Cu50
- Ni100
- Ni1000
- Ni500
- Pt100
- Pt1000
- Pt500
Sensor, Probe Connection
- 3-Wire
- 4-Wire
Sensor, Probe Diameter
- 0.23" (6 mm)
- 0.25" (6.4 mm)
Sensor, Probe Type
- E Thermocouple
- J Thermocouple
- K Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
Span - Minimum
- 20° C (68° F) for Model 8080PN
Stability
- 0.1 % of Calibrated Range ± 1-Digit over 6 Months for Model 8080PR, Model 8080PN
- Long Term Stability: ≤ 0.05 %/Year
Storage Temperature
- -40° to 100° C (-40° to 212° F)
Supply Voltage
- 10.5-45 Vdc (with Backlight LCD) for Model 8080HT
- 18-28 Vdc for Model 8080PR, Model 8080PN
Temperature Effect
- ± 0.01° C (± 0.018° F) for Model 8080PN
Temperature Range
- Calibration Temperature: 23° C (73.4° F) ± 5K
- RTD: -200° to 850° C (-328° to 1,562° F)
- Thermocouple: -270° to 1,820° C (-454° to 3,308° F)
Voltage