Yodify Product Library
Instantly add the FFU Flow Sensor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
FFU Flow Sensor
Brand: Sick AGThe non-contact FFU ultrasonic flowmeter detects the flow volume of conductive and non-conductive liquids.
Swimming against the current requires more strength than with the current – this is the simple fact on which ultrasonic flow measurement according to the phase difference process is based.
Its compact design enables the device to be used in a wide range of applications, including those with limited space.
This sensor with an enclosure rating of IP67 features a seal-free sensor design with high-quality polysulfone (Ultrason S), which not only makes it possible to use the device in harsh ambient conditions, but also ensures high process reliability.
The large cleartext display also helps provide simple, fast, and hassle-free commissioning.
Features- Maintenance-free flow sensor; reduces maintenance costs
- Adjustable measuring ranges, reduced number of variants
- Can be used for conductive and non-conductive liquids, reducing both the number of variants and storage costs
- Straight measuring tube reduces pressure loss, thus reducing energy costs
- Sensor without seals increases process reliability and availability
- Flexible measuring device for all industries
1 - 12 of 43 Part Numbers
6041249
- Nominal Width Measuring Tube - DN 15
- Process Connection - G 3/4"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS15-1G1IO
6041737
- Nominal Width Measuring Tube - DN 10
- Process Connection - G 1/2"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS10-1G1IO
6041738
- Nominal Width Measuring Tube - DN 20
- Process Connection - G 1"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS20-1G1IO
6041739
- Nominal Width Measuring Tube - DN 25
- Maximum Flow - Max. 240 L/min
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/ Status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS25-1G1IO
6043743
- Nominal Width Measuring Tube - DN 10
- Process Connection - G 1/2"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 2 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, 1 Switching Input for Dosing and Counter Reset
- Type - FFUS10-1G1SR
6043744
- Nominal Width Measuring Tube - DN 15
- Process Connection - G 3/4"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 2 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, 1 Switching Input for Dosing and Counter Reset
- Type - FFUS15-1G1SR
6043745
- Nominal Width Measuring Tube - DN 20
- Process Connection - G 1"
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 2 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, 1 Switching Input for Dosing and Counter Reset
- Type - FFUS20-1G1SR
6044523
- Nominal Width Measuring Tube - DN 25
- Maximum Flow - Max. 240 L/min
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/ Status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS25-1C1IO
6044996
- Nominal Width Measuring Tube - DN 25
- Maximum Flow - Max. 240 L/min
- Process Connection - 1-1/4" NPT
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/ Status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Process Temperature - 0° to 80° C
- Type - FFUS25-1N1IO
6045162
- Nominal Width Measuring Tube - DN 15
- Process Connection - Clamp, DIN11864-3
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS15-1C1IO
6047868
- Nominal Width Measuring Tube - DN 10
- Process Connection - 1/2" NPT
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS10-1N1IO
6047869
- Nominal Width Measuring Tube - DN 15
- Process Connection - 3/4" NPT
- Output Signal - Analog Output 4-20 mA, 0-20 mA Current Flow and Temperature, 1 Pulse/status Output PNP/NPN-Transistor Output for Flow Rate meter, Empty Pipe Detection, Flow Monitoring, Dosing Output, Flow Direction (Dependent on Type)
- Type - FFUS15-1N1IO
1 - 12 of 43 Part Numbers
Specifications
Brand
Enclosure Rating
- IP67
Certifications & Approvals
- CE
Nominal Width Measuring Tube
- DN10
- DN15
- DN20
- DN25
- DN32
- DN40
Process Temperature
- 0° to 80° C
Process Pressure
- ≤ 16 bar
Maximum Flow
- ≤ 21 to 240 L/min
Process Connection
- Clamp (DIN 11864-3)
- GF Connection G 2-3/4”
- GF Connection G 2-1/4”
- GF Connection G 2”
- GF Connection G 1-1/2”
- G 1-1/4”
- G 1”
- G 3/4”
- G 1/2”
- 1-1/4” NPT
- 3/4” NPT
- 1/2” NPT
- 1” NPT
Connection Type
- M12 Round Connector x 1, 8-Pin
- Round Connector M12 x 1, 5-Pin
Wetted Material
- PPSU
- EPDM
- Flow Measurement
- Flow Monitoring
- Flow Control