Yodify Product Library
Instantly add the GS 657/658 Galvanostat and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for the measurement of pressure and temperature.
Features
  • Short response time
  • Protection IP54
  • Electrical connection on terminal screw

Specifications

Accuracy

  • ± 3 % of Full Scale - Typical

Ambient Temperature Range

  • -30° to 70° C (-22° to 158° F)

Applications

  • Process Applications
  • Remote Sensing Thermostat

Approvals & Certifications

  • EN 60730-1, EN 60730-2-9

Capillary Length

  • 0 to 5,000 mm

Electrical Connectors

  • Terminal Screw: 3 x 1 to 2.5 mm²

Electrical Rating

  • 0.1 (0.1) A at 24 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 0.2 (0.02) A at 250 Vdc for Small Switching Differential, Not Adjustable
  • 0.25 (0.03) A at 250 Vdc for Average Switching Differential, Not Adjustable
  • 0.4 (0.03) A at 125 Vdc for Small Switching Differential, Not Adjustable
  • 0.5 (0.05) A at 125 Vdc for Average Switching Differential, Not Adjustable
  • 1 (1) A at 12 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 10 (0.75) A at 500 Vac for Average Switching Differential, Not Adjustable
  • 10 (1.25) A at 250 Vac for Small Switching Differential, Not Adjustable
  • 10 (1.5) A at 125 Vac for Small Switching Differential, Not Adjustable
  • 15 (1.25) A at 250 Vac for Average Switching Differential, Not Adjustable
  • 15 (1.5) A at 125 Vac for Average Switching Differential, Not Adjustable
  • 15 (2.5) A at 14 Vdc for Small Switching Differential, Not Adjustable
  • 2 (1) A at 30 Vdc for Small Switching Differential, Not Adjustable
  • 2 (2) A at 5 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 6 (1.5) A at 30 Vdc for Average Switching Differential, Not Adjustable

Enclosure, Body Material

  • ABS-Blend V0
  • Polycarbonate

Environmental Protection

  • IP54

Fill Material

  • Liquid

Gland Material

  • Screwed Cable Gland: Polyethylene (PE)

Humidity

  • Maximum

Insulation Resistance

  • > 2 megaohms

Materials of Construction

  • Fixing: Angle PVC

Measuring Range

  • 5° to 150° C (41° to 302° F)

Mounting Position

  • Any Orientation

Repeatability

  • ± 0.5 % of Full Scale

Sensor, Probe Material

  • Sensor: Copper with Protection Tube Teflon FEP

Set Point - Decreasing

  • 5° to 150° C (41° to 302° F)

Set Point - Increasing

  • 5° to 150° C (41° to 302° F)

Storage Temperature

  • -30° to 85° C (-22° to 185° F)

Voltage

  • Dielectric Strength: 1.45 kV (U ≤ 250 V)
  • Dielectric Strength: 2 kV (U ≤ 500 V)

  • Process Technology

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more