Yodify Product Library
Instantly add the SMART BILGE and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

The SMART BILGE 15ppm Oil Content Monitor was developed in 2005 to meet and exceed the requirements for MEPC.107(49) regulations.

The SMART BILGE is made up of 2 key components, the SMART BILGE ‘Module’ and the SMART ‘CELL’ measuring cell.

The SMART CELL utilises a unique Detector Array Technology, developed by Rivertrace, allowing the OCM to analyse all three oil types (HFO, Diesel and Emulsions) simultaneously without the need for re-calibration.

This innovative design allows for simple routine maintenance of the OCM while maintaining optimal conditions.

Optical cell fouling is recognised as a leading cause of monitor malfunction or incorrect reading. A manual cell cleaning device is included as standard to easily enable routine maintenance.

Replacement calibrated measuring cells can be purchased for easy change over on board the vessel and calibration check kits enable the crew to demonstrate the monitor is within factory calibration to PSC Surveyors.
Features
  • Digital Certifications
  • Automated electronic calibration reminders
  • Over 50 approved service centres worldwide for calibration checks and service
  • Separate Calibrated SMART CELL to allow easy exchange
  • Test button for demonstration of alarm points to port state control

Specifications

Oil Types

  • HFO, Diesel and Mixture C (IMO defined)

Clean Water Calibration

  • ± 2 ppm of factory set values

Oil Range

  • 0 - 40 ppm

Accuracy Oil + Solids

  • ± 5 ppm up to 30 ppm

Solids Discrimination

  • 100 ppm Iron Oxide in 10 ppm Diesel

Response Time

  • < 5 sec (oil reading)

Oil Alarm 1 Setpoint

  • 1 - 15 ppm user adjustable

Oil Alarm 2 Setpoint

  • 1 - 15 ppm user adjustable

Oil Alarm 1 Delay

  • 0 - 5 seconds user adjustable

Oil Alarm 2 Delay

  • 0 - 600 seconds user adjustable

Analogue Output

  • Active 4-20 mA / 0-20 mA

Switch Inputs

  • 2 x switch inputs for separator and backflush status

Calibrate On Data Storage

  • Stored in cell

IMO Required Data

  • Stored in Control enclosure

IMO Required Data Retrieval

  • Via LCD display, RS-232 comms link or USB

Supply Voltage

  • 115 or 230 Vac, 50/60 Hz (24 Vac & 12 Vdc available)

Supply Voltage Consumption

  • < 50 VA including solenoid valve

Supply Voltage Tolerance

  • ± 15 %

Projected Life

  • > 50,000 hours

Protection Class

  • IP65

Approvals

  • MEPC 107(49) - DNV-GL, USCG, CCS, , Russian Register, Transport Canada.

Weight

  • 3.2 kg/7.05 lb

  • MEPC.107(49) Bilge Water Discharge
  • Oily Water Separator
  • Deck Drains Discharge
  • Rig Slop Tank Discharge