Yodify Product Library
Instantly add the IPS-RV Intelligent Pump Soft Starter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

IPS-RV Intelligent Pump Soft Starter

Brand: Franklin Electric Co, Inc.

Tru-power™ sensing protects the IPS-RV from dry-run, dead head, runout, and jammed impeller conditions - keeping you online and preventing costly premature pump failure. Along with superior protection, measuring underload using power allows for a more flexible trip range, as opposed to measuring by current, which requires a more precise set point. The end result is the elimination of nuisance trips.

Easy to setup and use
Inside, the display shows an easy to use menu for setting a wealth of parameters. Adjust any protective or control setting in seconds. For example, choose how long to allow for dry well recovery, set run time periods, and On/Off delays. All this with just a few intuitive keystrokes. The IPS-RV ships with factory default settings pre-programmed for optimal submersible pump protection.
Industrial grade construction
  • Door mounted heavy-duty HOA switch
  • Housed in an outdoor rated, gasketed, NEMA 3R enclosure
  • Multi-tap control power transformer with integrated secondary protection accommodates common motor voltages. No fuses required!
  • Includes 120 VAC control power for field devices
Advanced programmable pump control
  • Automatic fault reset
  • Backspin delay - Prevents start-ups into draining systems
  • On and Off delay settings
  • Well recovery mode (up to 48 hours)
  • Minimum run time based on last input
  • 12-120 V input for remote start/stop
  • Dry contact input for remote start/stop
  • Dry contact inputs for float switches
  • Analog input for (selectable) 0-10V, 4-20mA, or 10k thermistor, viewable as a Modbus point
Optional circuit breaker disconnect (Service Entrance rated)
  • UL 489 circuit breaker provides branch and short circuit protection
  • No fuses required – saves time and money
  • Lockable handle for safety
Built-in power monitoring, fault logging and communications
  • View voltage, current, power factor, and more through an intuitive display
  • Built-in fault log, counter and parameter change log: records last 15 fault types with power condition values, stores how many times each fault type has occurred (up to 255 count), and logs changes to parameter settings (e.g. FLA, OV/UV, under power)
  • Built-in Modbus RTU communications card
Features
  • Full HP rated bypass contactor
  • Across-the-line start for emergency situations (turns the soft-starter into a standard IPS)
  • Start modes feature an adjustable current limit, initial voltage, and start time with a torque boost feature
  • Stop modes include:
  • Coast to stop
  • Linear deceleration (reduces water-hammer effect)
  • Adjustable stop voltage and stop time
  • SCR over-temperature detection
  • Shorted SCR detection

1 - 12 of 44 Part Numbers
IPS3R-RV-S1-6J-G15
IPS3R-RV-S1-6J-G15
Minimum Current: 6A, Maximum Current: 8A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1-6J-G20
IPS3R-RV-S1-6J-G20
Minimum Current: 8A, Maximum Current: 11A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1-6J-G30
IPS3R-RV-S1-6J-G30
Minimum Current: 11A, Maximum Current: 17 A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1-6J-G40
IPS3R-RV-S1-6J-G40
Minimum Current: 16 A, Maximum Current: 22 A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1-J-G15
IPS3R-RV-S1-J-G15
Minimum Current: 6A, Maximum Current: 8A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
IPS3R-RV-S1-J-G20
IPS3R-RV-S1-J-G20
Minimum Current: 8A, Maximum Current: 11A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
IPS3R-RV-S1-J-G30
IPS3R-RV-S1-J-G30
Minimum Current: 11A, Maximum Current: 17 A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
IPS3R-RV-S1-J-G40
IPS3R-RV-S1-J-G40
Minimum Current: 16 A, Maximum Current: 22 A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
IPS3R-RV-S1P-6J-G50
IPS3R-RV-S1P-6J-G50
Minimum Current: 20 A, Maximum Current: 27 A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1P-6J-G60
IPS3R-RV-S1P-6J-G60
Minimum Current: 24 A, Maximum Current: 34 A, Branch Protection Included: Yes, Volts: 575 VAC
IPS3R-RV-S1P-J-G50
IPS3R-RV-S1P-J-G50
Minimum Current: 20 A, Maximum Current: 28 A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
IPS3R-RV-S1P-J-G60
IPS3R-RV-S1P-J-G60
Minimum Current: 34 A, Maximum Current: 34 A, Branch Protection Included: Yes, Volts: 208-230 VAC / 460 VAC
1 - 12 of 44 Part Numbers

Specifications

Overload

  • Overload Selectable Class 5-30, trips within inverse trip curve

Ground Fault

  • UL 1053 ground fault protection

Voltage

  • 208-230 VAC / 460 VAC
  • 575 VAC
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more