Brand: R. STAHL AG

R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. 

The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
Features
  • Safe switching to protect Ex e motors
  • Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release
  • Optional undervoltage release and shunt trip
  • Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

1 - 12 of 89 Part Numbers
146630
146630
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 0.10 - 0.16 A
  • Current-setting range max. - 0.16 A
  • Min. current-setting range - 0.10 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-01-000
  • Title Product Variant Technical Data - 8523/81-01-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.380 kg
146632
146632
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 0.25 - 0.40 A
  • Current-setting range max. - 0.40 A
  • Min. current-setting range - 0.25 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-03-000
  • Title Product Variant Technical Data - 8523/81-03-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.365 kg
146634
146634
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 0.63 - 1.00 A
  • Current-setting range max. - 1.00 A
  • Min. current-setting range - 0.63 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-05-000
  • Title Product Variant Technical Data - 8523/81-05-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.348 kg
146635
146635
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 1.00 - 1.60 A
  • Current-setting range max. - 1.60 A
  • Min. current-setting range - 1.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-06-000
  • Title Product Variant Technical Data - 8523/81-06-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.410 kg
146636
146636
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 1.60 - 2.50 A
  • Current-setting range max. - 2.50 A
  • Min. current-setting range - 1.60 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-07-000
  • Title Product Variant Technical Data - 8523/81-07-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.400 kg
146637
146637
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 2.50 - 4.00 A
  • Current-setting range max. - 4.00 A
  • Min. current-setting range - 2.50 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-08-000
  • Title Product Variant Technical Data - 8523/81-08-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.407 kg
146638
146638
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 4.00 - 6.30 A
  • Current-setting range max. - 6.30 A
  • Min. current-setting range - 4.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-09-000
  • Title Product Variant Technical Data - 8523/81-09-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.419 kg
146639
146639
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 6.30 - 9.00 A
  • Current-setting range max. - 9.00 A
  • Min. current-setting range - 6.30 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-10-000
  • Title Product Variant Technical Data - 8523/81-10-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.408 kg
146641
146641
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 12.50 - 16.00 A
  • Current-setting range max. - 16.00 A
  • Min. current-setting range - 12.50 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-12-000
  • Title Product Variant Technical Data - 8523/81-12-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.406 kg
146642
146642
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 16.00 - 20.00 A
  • Current-setting range max. - 20.00 A
  • Min. current-setting range - 16.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-13-000
  • Title Product Variant Technical Data - 8523/81-13-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.440 kg
146643
146643
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 20.00 - 22.50 A
  • Current-setting range max. - 22.50 A
  • Min. current-setting range - 20.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-14-000
  • Title Product Variant Technical Data - 8523/81-14-000 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.405 kg
217698
217698
R. STAHL Moulded Case Circuit Breaker for Motor Protection
Safe switching to protect Ex e motors

Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release

Optional undervoltage release and shunt trip

Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Current-setting range - 0.40 - 0.63 A
  • Current-setting range max. - 0.63 A
  • Min. current-setting range - 0.40 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 415.00 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 01 ATEX E 153 U
  • ATEX gas certificate - DMT 01 ATEX E 153 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 08.0039U
  • IECEX gas certificate - IECEx BVS 08.0039U

General

  • Functional Description - R. STAHL Series 8523/8 motor protection moulded case circuit breakers are equipped with a non-adjustable fast short-circuit release and a thermal overcurrent release adjustable at the switch. The switches are operated via a rotary actuator, whereby the switch position is always easy to see. You can set the various current ranges.
  • Highlights - Safe switching to protect Ex e motors Release: Non-adjustable fast short-circuit release, adjustable thermal overcurrent release Optional undervoltage release and shunt trip Optional auxiliary contacts: 1 NC + 1 NO or 2 NC + 2 NO
  • Product Description - Moulded case circuit breaker For motor protection
  • Product Type - 8523/81-04-108
  • Title Product Variant Technical Data - 8523/81-04-108 circuit breaker for motor
  • WebCode - 8523A

Mechanical Data

  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section min. - 1.50 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Enclosure material - Epoxy resin or polyester resin
  • Enclosure size - 130x80x110,5
  • Service life, min. - 100,000 operating cycles
  • Weight - 1.420 kg