S9200U1000/U Universal Hot Surface Ignition Integrated Furnace Control
Brand: Resideo Technologies IncUniversal Integrated Furnace Control offers universal compatibility and diagnostics.
It replaces a large number of furnace control models in single-stage warm air furnaces.
Uses 120Vac hot surface igniter.
Includes instructions and special wire harnesses for easy replacement.
Features- Cross Reference and Wire Harnesses Provided for Simple Replacement Over 195 Existing Furnace Controls.
- Main Burner Ignition Using a 120V Hot Surface Igniter.
- Flame Rectification Circuit to Monitor Flame Presence.
- Monitoring of System Pressure Switch, High Temperature Limit, and Rollout Functions.
- Appliance Operation/Safety Requirements Controlled via Microprocessor.
- Controls Circulating Fan Motor Based on Appliance Requirements, in Response to a Conventional Low Voltage Thermostat.
- Led System Status, Performance and Diagnostic Indication.
- Twinning Capability
Specifications
Brand
Frequency
- 60 Hz
Operating Humidity Range
- 0% to 95% non-condensing
Operating Temperature Range
- -40 °F to +175 °F
- -40 °C to +79 °C
Flame Failure Response Time
- 2 Seconds max @ 1µA
PrePurge
- 30 seconds
PostPurge
- 15 seconds
Cool Fan On Delay
- 5 seconds
Cool Fan Off Delay
- 0 or 60 seconds
Line Voltage
- 120 Vac (97-132 Vac)
Low Voltage
- 24V (18-30 Vac)
Igniter Current
- 5 A resistive @ 120VAC
Thermostat Anticipator Setting
- (Stage 1 only) 100mA
HSI Warmup Time
- 17/27 or 30/30 seconds
Trial for Ignition
- 4, 6, or 8 seconds
Interpurge
- 60 seconds
Ignition Trials
- Three, two tries if flame is not sensed
Number of LEDs
- 3
Heat On Fan Delay
- 30 or 60 seconds
Heat Off Fan Delay
- 60, 90, 120, or 180 Seconds
Gas Control Used With
- Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With
- Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load
- 2.2FLA / 25LRA max @120Vac
Ciculator Load
- 14.5FLA / 25LRA max @120Vac
Type of Fan Used With
- Standard Induction-Type Circulating Fan
- Single Stage Warm Air Furnaces