Nelson™ Heat Trace Splice Connection Kits

Brand: Nelson

Nelson™ Heat Trace splice connection kits are used to connect two heater cables to each other in a splice configuration. 

It may be used to extend cable length, connect different wattage cables together or to provide access to service removable equipment. 

AXSC100 is designed per NEC/CEC requirements including standard terminal blocks sized for maximum 8 AWG wiring. 

EXSC100 is designed per IEC requirements including standard terminal blocks sized for maximum 6mm² wiring. 

HSC100 splice kit is offered without an enclosure for customers who provide the connection enclosure. 

Kits are used to connect and terminate Nelson™ Heat Trace LT-J, LT-JT, HLT-J, XLT-J and CLT-JT Series self-regulating heater cables.
Features
  • Ordering information: One kit should be ordered for each type of connection needed. A pipe clamp of the appropriate size for the pipe must be selected (-3 for PC03, -12 for PC12, -20 for PC20) for each connection kit. A small pipe adapter kit must be ordered for each kit for installation on 25 mm (1 inch) or smaller pipe.
  • The enclosure must be rated to meet the specifics of the installed environment.
  • Global-reach industrial-grade universal connection kits for hazardous locations.
  • Certified for NEC/CEC (AX Series) and IEC (EX Series) installations.
  • Incorporate rugged, non-metallic construction rated for IP66 / NEMA 4X.
  • Designed with corrosion resistant, antistatic enclosures and components.
  • Easy entry and connectivity with terminal blocks and DIN rails.
  • Fits all wattages of Nelson™ LT-J, LT-JT, HLT-J, XLT-J and CLT-JT Series self-regulating heater cables.

Specifications

Brand

Accessories

  • Pipe Clamp to Secure Standoff to Pipe & a Small Pipe Adapter are available. See Catalog Pages for Details

Amperage, Maximum

  • 14 A CLT Series, 18 A LT, HLT Series, 25 A XLT Series

Approvals & Certifications

  • UL Listed, CSA & ATEX Certified, FM Approved: Hazardous (Classified) Locations

Approvals & Certifications

  • Ex II 2 G, Ex E IIC T5 Gb, Ex II 2 D, Ex Tb IIIC T95° C

Conductor Size

  • 1 mm² (18 AWG) to 6 mm² (8 AWG)

CSA

  • Class I, Div. 2, Groups B, C, D, Class II, Groups E, F, G (Canada Only), Class III (Canada Only), Enclosure Typical 4X, Class I, Zone 1, Ex E II

Enclosure Material

  • Glass Reinforced, Carbon-loaded, Polyester, UV Resistant, Polymer

FM

  • Class I, Div. 2, Groups B, C, D, Class II, Groups E, F, G, Class III, Enclosure Typical 4X, IP66, Class I Zone 1, AEx E IIC

Ingress Protection

  • NEMA 4X, IP66

Minimum Installation Temperature

  • -40° C (-40° F)

Temperature Use Range

  • -50° to +55° C (-58° to +131° F) Ambient

UL

  • Class I, Div. 2, Groups A, B, C, D, Class II, Div. 2, Groups F, G, Class III, Div. 1, & 2

Voltage Range

  • 300 Vac, Max.