Yodify Product Library
Instantly add the Fire Alarm Stations Series 8146/5052 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Fire Alarm Stations Series 8146/5052
Brand: R. STAHL AGWith the R. STAHL Series 8146/5052 fire alarm stations, you can manually trigger alarms in hazardous areas. Smash the glass pane using the emergency hammer attached to the side and trigger the alarm using the button.
The alarms are available in three different variants for tripping and disconnecting the alarm.
Features- Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin
- 3 versions with manual or automatic alarm triggering and disconnection via switch or key
- Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series
1 - 3 of 3 Part Numbers
136126
Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin
3 versions with manual or automatic alarm triggering and disconnection via switch or key
Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
Components
- Screw connections - 1 x M25 x 1.5
Electrical Data
- Ex version - Yes
- Rated operational voltage AC - 500.00 V
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 01 ATEX 1105
- ATEX gas certificate - PTB 01 ATEX 1105
- Certificate EAC - TS RU S-DE.AA71.B.00113
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), Canada / USA (UL), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tD T80 °C
- Dust explosion protection IECEx - Ex tD T80 °C
- Gas explosion protection ATEX - II 2 G Ex de IIC T6 Gb
- Gas explosion protection IECEx - Ex de IIC T6 Gb
- IECEX dust certificate - IECEx PTB 06.0025
- IECEX gas certificate - IECEx PTB 06.0025
General
- Functional Description - With the R. STAHL Series 8146/5052 fire alarm stations, you can manually trigger alarms in hazardous areas. Smash the glass pane using the emergency hammer attached to the side and trigger the alarm using the button. The alarms are available in three different variants for tripping and disconnecting the alarm.
- Highlights - Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin 3 versions with manual or automatic alarm triggering and disconnection via switch or key Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series
- Product Description - Fire Alarm Stations
- Product Type - 8146/5052-C796
- Title Product Variant Technical Data - 8146/5052-C796 Fire Alarm Station
- WebCode - 8146G
Mechanical Data
- Cable entry max. - 17.00 mm
- Cable entry min. - 7.00 mm
- Connection terminals finely-stranded max. - 2.50 mm²
- Contacts - 1 NC + 1 NO
- Degree of protection (IP) - IP65
- Enclosure colour - red (RAL 3000)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 131.000 mm
- Length - 230.000 mm
- Type of connection cable - Finely stranded
- Version - Mushroom stay-put button
- Weight - 2.270 kg
- Width - 170.000 mm
136128
Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin
3 versions with manual or automatic alarm triggering and disconnection via switch or key
Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
Components
- Screw connections - 1 x M25 x 1.5
Electrical Data
- Ex version - Yes
- Rated operational voltage AC - 500.00 V
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 01 ATEX 1105
- ATEX gas certificate - PTB 01 ATEX 1105
- Certificate EAC - TS RU S-DE.AA71.B.00113
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), Canada / USA (UL), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tD T80 °C
- Dust explosion protection IECEx - Ex tD T80 °C
- Gas explosion protection ATEX - II 2 G Ex de IIC T6 Gb
- Gas explosion protection IECEx - Ex de IIC T6 Gb
- IECEX dust certificate - IECEx PTB 06.0025
- IECEX gas certificate - IECEx PTB 06.0025
General
- Functional Description - With the R. STAHL Series 8146/5052 fire alarm stations, you can manually trigger alarms in hazardous areas. Smash the glass pane using the emergency hammer attached to the side and trigger the alarm using the button. The alarms are available in three different variants for tripping and disconnecting the alarm.
- Highlights - Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin 3 versions with manual or automatic alarm triggering and disconnection via switch or key Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series
- Product Description - Fire Alarm Stations
- Product Type - 8146/5052-C797
- Title Product Variant Technical Data - 8146/5052-C797 Fire Alarm Station
- WebCode - 8146G
Mechanical Data
- Cable entry max. - 17.00 mm
- Cable entry min. - 7.00 mm
- Connection terminals finely-stranded max. - 2.50 mm²
- Contacts - 1 NC + 1 NO
- Degree of protection (IP) - IP65
- Enclosure colour - red (RAL 3000)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 131.000 mm
- Length - 230.000 mm
- Type of connection cable - Finely stranded
- Version - Mhrm sty-pt but w/ key lock
- Weight - 2.270 kg
- Width - 170.000 mm
136137
Easily visible red (RAL 3000) enclosure made from glass fibre reinforced polyester resin
3 versions with manual or automatic alarm triggering and disconnection via switch or key
Short-circuit protection and open-circuit monitoring are possible thanks to the subsequent installation of a resistance module from the 8208 series