Brand: Delta OHM S.R.L.

DO9786T-R1 transmitters convert the output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.

Housing dimensions 96 x 96 mm for panel mounting with dual LCD (measurement + temperature), output 4…20mA. 

The cell constant, the range and the temperature coefficient are completely configurable. 2-wire passive transmitter or 4-wire active transmitter.

Power supply in active mode 24Vac, on request 230Vac, in passive mode 10…35Vdc.

The electrode input circuit is galvanically insulated against the 4÷20 mA output signal.

The LCD indicator allows viewing of the process signal value and of the various parameters. 

The accurate design and choice of components make the instrument precise and reliable for a long working life.

The instrument works in conjunction with a conductivity electrode and a temperature probe (Pt100 sensor, 100 Ω at 0°C).

1 - 12 of 14 Part Numbers
CP5/10T
CP5/10T
10 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP5/20T
CP5/20T
20 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP5T
CP5T
5 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
DO9766T-R1
DO9766T-R1
Conductivity Transmitter 4…20 mA Passive or Active. For Use On The Field
DO9786T-R1
DO9786T-R1
Conductivity Transmitter 4…20 mA Passive or Active. For Panel Mounting
HD8700C
HD8700C
ACCREDIA ISO 17025 Certified Standard Solutions Kit
ACCREDIA ISO 17025 certified standard solutions kit: 0.001mol/l (147 μS/cm @ 25 °C) + 0.01mol/l (1413 μS/cm @ 25 °C) + 0.1mol/l (12880 μS/cm @ 25 °C). Two 50 ml bottles for each type (6 bottles in total).
HD882/L106
HD882/L106
Temperature Probe For Industrial Use, Pt100 Sensor, Shaft Ø6 x 45 mm.
HD882DM100/600
HD882DM100/600
Temperature Probe With Pt100 Sensor, DIN B Head, Stem Length 600 mm.
SPT401.001/W
SPT401.001/W
Combined Conductivity And Temperature Probe With 2 Stainless Steel AISI316 Electrodes, Cell Constant 0.01
Combined conductivity and temperature probe with 2 stainless steel AISI316 electrodes, cell constant 0.01. Probe measuring range 0.04…20 μS, 0…120 °C. 4-pole connector. Supplied with cable with 4-pole connector on one side and free wires on the other side.
SPT86
SPT86
Cell Constant K= 0.7, 1.5 m Cable, Temperature Working Range 0…90°C.
4-electrode combined conductivity and temperature probe with Pt100 sensor. Cell constant K= 0.7, 1.5 m cable, temperature working range 0…90°C.
SPTKI10
SPTKI10
Cell Constant K = 1, Temperature Working Range 0…100 °C.
Industrial conductivity probe in glass with 2 platinum electrodes, S7 - PG13.5 connector, cell constant K = 1, temperature working range 0…100 °C.
SPTKI11
SPTKI11
Cell Constant K = 1, 2-wire Pt100, Temperature Working Range 0…80 °C.
Combined industrial conductivity and temperature probe in Rytron with 2 platinum electrodes, 3/4” BSP connector, 5 m cable, cell constant K = 1, 2-wire Pt100, temperature working range 0…80 °C.
1 - 12 of 14 Part Numbers

Specifications

Input Conductivity

  • Input: impedance > 10^12 Ω
  • Cable length: < 50 meters screened (about 5 nF)
  • Accuracy: 0.1 % of Reading ± 1-Digit ± 0.01 % of pH per °C of temperature drift
  • Measuring Range: 0.0…199.9 mS
  • 2/4 electrodes: Configurable cell constant 0.0…199.9 cm-1
  • Transducer Energizing: Square wave 10…1000 mV, 200…1600 Hz, depending on conductivity

Temperature Input

  • Pt100 2/4-Wires: -50…199.9° C
  • Transducer energizing: 0.5 mA DC
  • Cable length: < 10 metres unscreened < 50 metres screened (about 2 nF)
  • Accuracy: 0.2° C ± 0.1 % of Reading ± 0.01° C/°C

Compensation Temperature

  • Automatic: Linear 0.00…4.00 %/°C -50…+200° C
  • Manual: Linear 0.00…4.00 %/°C -50…+200° C
  • None:
  • Reference temperature: 20 or 25° C configurable

Current Output

  • 4…20 mA: Programmable and proportional to conductivity
  • Accuracy: 0.5 % of Reading ± 0.02 mA
  • Insulation: 2500 Vac 1 minute

R Load

  • Load resistance: RLmax = Vdc-10/0,022 RLmax= 636 Ω @ Vdc = 24 Vdc

Relay Output

  • A and B: Bistable, contact 3 A/230 Vac free potential

Power Supply

  • Active:24 Vac (or 230 Vac on request) -15/+10 %, 1 VA, 48…62 Hz
  • Passive: 4…20 mA, 2-Wire configuration, 10…35 V

Case DO9766T

  • External dimensions: 120 x 122 x 56 mm (use on the field)
  • Protection class: IP64

Case DO9786T

  • External dimensions: 96 x 96 x 126 mm (panel mounting)
  • Protection class: IP44