Yodify Product Library
Instantly add the AX430 Single Channel Transmitter for 4-Electrode Conductivity Cell and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
AX430 Single Channel Transmitter for 4-Electrode Conductivity Cell
Brand: ABB GroupThe AX430 conductivity transmitter is designed for use with ABB’s 4-electrode conductivity cells to measure conductivity with exceptional accuracy and performance.
It incorporates the latest technology to provide a highly reliable, flexible, feature-packed device that satisfies a diverse range of process monitoring and control applications.
Features- Cost effective
- select one or two conductivity inputs or combine pH/Redox (ORP) with conductivity in one analyzer
- integral PID controller
- Advanced measuring capabilities
- conductivity range up to 1,999 mS cm-1
- selectable concentration ranges:
- 0 to 15% NaOH, 0 to 18% HCl, 0 to 20% H2SO4
- 0 to 40% H3PO4, 0 to 20% NaCl and user-defined
- Dosing control functionality
- long dose diagnostic alarm
- initial charge function
- Reduced installation cost
- easy access terminations; reduced panel space
- High functionality at minimum cost
- three alarms and two fully-isolated current outputs
- direct linear, reverse acting or bi-linear output
- Expanded monitoring and control
- add-on option board provides a total of five alarm relays and four current outputs
- service logbook providing historical data
- Reduced yearly maintenance costs
- 12 to 30 Vdc option negates the need for costly safety tests
1 - 12 of 90 Part Numbers
AX43010001
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43010002
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43010003
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43010101
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43010102
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43010103
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011001
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011002
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011003
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011101
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011102
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43011103
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
1 - 12 of 90 Part Numbers
Specifications
Brand
Range
- 0 to 2,000 mS/cm
- Concentratio: Up to 15 % NaOH, 18 % HCl, 20 % H₂SO4 or NaCl, or 40 % H3PO4
Mounting
- Wall Mounting
- Pipe Mounting
- Panel Mounting
Environmental Protection
- IP66
- NEMA 4X
Temperature Sensor
- Pt1000 or 3k Balco
Display
- Dual 5-digit, 7-segment backlit LCD
Communication
- PROFIBUS DP
Controller Type
- P, PI, PID (Configurable)
Control Output
- Derivative: 0.1 to 999.9 s in increments of 0.1 s
- Proportional Band: 0.1 to 999.9 %
- Pulse frequency: 1 to 120 pulses per minute
- Time proportioning cycle Time: 1.0 to 300.0 s, Programmable in increments of 0.1 s
- Current output Control: 0 to 100 %
- Integral Action Time (Integral Reset): 1 to 7,200 s
Power Supply
- 85-265 Vac
- 12-30 Vdc
Power Consumption
- 10 W
Certifications & Approvals
- EMC
- CE
- UL
Operating Temperature
- -20° to 55° C (-4° to 131° F)
Storage Temperature
- -25° to 75° C (13° to 167° F)
Humidity
- Up to 95 % Relative Humidity Non-Condensing
- Regeneration of Ion Exchangers
- Municipal Water Phosphoric Acid Control
- Food & Beverage Product / Water Interface Detection
- Clean-in-Place Concentration Monitoring
Documentation
Brochure
Certificate
Manual
- Manual - AX413, AX430, AX433, AX436 and AX438 Single and Dual Input Analyzers for High-level Conductivity pdf
- Manual - User guide supplement - AX400 series | Single and dual input analyzers | PROFIBUS® datalink description pdf 602 KB
- Instruction - AX4xx and AV4xx series transmitters | Display driver selection | LCD display module (AX400/0295) pdf 1.7 MB