Yodify Product Library
Instantly add the 3051SAL Scalable Level Transmitter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

3051SAL Scalable Level Transmitter

Brand: Rosemount

Make reliable pressure measurements in extreme conditions with the Rosemount 3051SAL Level Transmitter, a best-in-class solution that offers enhanced capabilities for pressurized and vented tank level measurements. 

This transmitter is safety certified and engineered with advanced diagnostics for increased insight. Designed to allow direct mounting, remote mounting, balanced systems and Tuned-System™ assemblies, this device can meet a variety of demands and process requirements for level applications.
Features
  • Allows for direct mounting, remote mounting and balanced and tuned-systems to meet various application requirements
  • Tuned-Systems can reduce temperature effects by 10-20% and improve response time by 80% vs. traditional installations
  • Offers a variety of process connections including flanged, threaded and hygienic seals for application flexibility
  • Welded-repairable construction allows the seal system to be repaired and all welded design provides a robust connection for challenging applications
  • Scaled variable allows transmitter to output level units
  • Remote display offers direct mount process connections with access to transmitter interface at grade
  • SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
  • Advanced diagnostics offer diagnostic coverage to detect electrical loop issues and abnormal process conditions

Specifications

Brand

Accuracy

  • Classic: 0.065 % of Span Accuracy
  • Ultra: 0.055 % of Span Accuracy

Alarm

  • Custom Alarm & Saturation Signal Levels
  • NAMUR Alarm & Saturation Signal Levels

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Applications

  • Corrosive, Clogging, or Viscous Processes
  • Extreme Hot & Cold Temperatures
  • Hygienic Requirements
  • Level
  • Special Process Connections

Approvals & Certifications

  • ATEX
  • CSA
  • FM
  • IEC Ex
  • INMETRO
  • TIIS

Conduit Connection

  • A Size Mini, 4-Pin Male Connector (minifast)
  • M12, 4-Pin, Male Connector (eurofast)

Configuration

  • FOUNDATION Fieldbus Protocols
  • HART Protocols

Damping Adjustment

  • User Configurable from 0 to 60 seconds

Diaphragm Material

  • 304L Stainless Steel
  • 316 Stainless Steel
  • 316L Stainless Steel
  • 316Ti Stainless Steel
  • Alloy 22 (Hastelloy)
  • Alloy 400 or Monel
  • Carpenter 20 Stainless Steel
  • Duplex 2507 Stainless Steel
  • Hastelloy B
  • Hastelloy C-276
  • Inconel
  • Nickel 201
  • Tantalum
  • Titanium
  • Zirconium 702

Display

  • PlantWeb LCD Display
  • Remote Mount LCD Display & Interface

Drain, Vent Valves & Plug

  • 316 Stainless Steel

Electrical Connectors

  • 1/2” NPT
  • G 1/2”
  • M20 x 1.5

Electromagnetic Interference Effect

  • Approved According to EMC (2004/108/EC) EN 61326-1: 2006

Enclosure Finish

  • Polyurethane Paint

Enclosure, Body Material

  • 316 Stainless Steel
  • Aluminum

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X

Fill Material

  • DC 200, DC 704 or DC 705 Silicone Oil
  • Glycerin & Water
  • Inert HaloCarbon
  • Neobee M20
  • Propylene Glycol & Water
  • Syltherm XLT
  • Ultra Therm 805

Flange Material

  • 316L Stainless Steel

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#
  • 1-1/2” (DN 40) - 1500#
  • 1-1/2” (DN 40) - 2500#
  • 1-1/2” (DN 40) - 300#
  • 1-1/2” (DN 40) - 600#
  • 1-1/2” (DN 40) - 900#
  • 1-1/2” (DN 40) - JIS 10K
  • 1-1/2” (DN 40) - JIS 20K
  • 1-1/2” (DN 40) - JIS 40K
  • 1-1/2” (DN 40) - PN 40

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150#
  • 1” (DN 25) - 1500#
  • 1” (DN 25) - 2500#
  • 1” (DN 25) - 300#
  • 1” (DN 25) - 600#
  • 1” (DN 25) - 900#
  • 1” (DN 25) - JIS 10K
  • 1” (DN 25) - JIS 20K
  • 1” (DN 25) - JIS 40K
  • 1” (DN 25) - PN 40

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150#
  • 1/2” (DN 15) - 1500#
  • 1/2” (DN 15) - 2500#
  • 1/2” (DN 15) - 300#
  • 1/2” (DN 15) - 600#
  • 1/2” (DN 15) - 900#
  • 1/2” (DN 15) - JIS 10K
  • 1/2” (DN 15) - JIS 20K
  • 1/2” (DN 15) - JIS 40K
  • 1/2” (DN 15) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 1500#
  • 2” (DN 50) - 2500#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - 600#
  • 2” (DN 50) - 900#
  • 2” (DN 50) - JIS 10K
  • 2” (DN 50) - JIS 20K
  • 2” (DN 50) - JIS 40K
  • 2” (DN 50) - PN 10
  • 2” (DN 50) - PN 100
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 40
  • 2” (DN 50) - PN 63

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#
  • 3” (DN 80) - 1500#
  • 3” (DN 80) - 2500#
  • 3” (DN 80) - 300#
  • 3” (DN 80) - 600#
  • 3” (DN 80) - 900#
  • 3” (DN 80) - JIS 10K
  • 3” (DN 80) - JIS 20K
  • 3” (DN 80) - JIS 40K
  • 3” (DN 80) - PN 10
  • 3” (DN 80) - PN 100
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 40
  • 3” (DN 80) - PN 63

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 150#
  • 3/4” (DN 20) - 1500#
  • 3/4” (DN 20) - 2500#
  • 3/4” (DN 20) - 300#
  • 3/4” (DN 20) - 600#
  • 3/4” (DN 20) - 900#
  • 3/4” (DN 20) - JIS 10K
  • 3/4” (DN 20) - JIS 20K
  • 3/4” (DN 20) - JIS 40K
  • 3/4” (DN 20) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#
  • 4” (DN 100) - 1500#
  • 4” (DN 100) - 2500#
  • 4” (DN 100) - 300#
  • 4” (DN 100) - 600#
  • 4” (DN 100) - 900#
  • 4” (DN 100) - JIS 10K
  • 4” (DN 100) - JIS 20K
  • 4” (DN 100) - JIS 40K
  • 4” (DN 100) - PN 10
  • 4” (DN 100) - PN 100
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40
  • 4” (DN 100) - PN 63

Humidity

  • 0 to 100 % Relative Humidity

Input Power

  • 4-20 mA HART: 10.5-42.4 Vdc
  • FOUNDATION Fieldbus: 9-32 Vdc

Mounting

  • Direct Mount Seal System
  • Remote Mounting

NACE & NIST

  • NACE MR-0103, MR-0175

NPT Connection

  • 1” NPT Male
  • 1/4” NPT Male
  • 1-1/4” NPT Male
  • 3/4” NPT Male

O-Ring Material

  • Glass-Filled PTFE
  • Graphite-Filled PTFE

Output

  • 17.5 mA
  • 2.4 GHz DSSS
  • 2-Wire 4-20 mA

Overpressure & Static Pressure Limits

  • 0 psia to the Flange Rating or Sensor Rating, whichever is Lower

Power Supply Effect

  • < ± 0.005 % of Calibrated Span Per Volt Change in Voltage at the Transmitter Terminals

Pressure Range

  • bar: -137.9 to 689.5
  • inches WC: -1,000 to 1,000
  • kPa: -13,790 to 13,790
  • psi: -2,000 to 10,000

Pressure Type

  • Absolute
  • Differential
  • Gauge

Process Temperature

  • Up to 410° C (770° F)

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Tri-Clamp Connection

  • 1-1/2” Sanitary Clamp
  • 2” Sanitary Clamp
  • 3” Sanitary Clamp

Vibration Effect

  • > ± 0.1 % of URL

Volumetric Displacement

  • > 0.005”³ (0.08 cm³)

Wetted Materials

  • 304L Stainless Steel
  • 316 Stainless Steel
  • 316L Stainless Steel
  • 316Ti Stainless Steel
  • Alloy 22 (Hastelloy)
  • Alloy 400 or Monel
  • Carpenter 20 Stainless Steel / Alloy 20 or Incoloy
  • Duplex 2507 Stainless Steel
  • Hastelloy B
  • Hastelloy C-276
  • Inconel
  • Nickel
  • Tantalum
  • Titanium
  • Zirconium 702
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more