Yodify Product Library
Add the Model IFMA DIN Rail Frequency to Analog Converter to your store or catalog
Book Your Demo and See How
or create your store
Model IFMA DIN Rail Frequency to Analog Converter
Brand: Red Lion ControlsThe Model IFMA accepts a frequency input, and outputs an Analog voltage or current in proportion to the input frequency, with 0.1% accuracy.
The full scale input frequency can be set to any value from 1 Hz to 25 KHz, either with a frequency source, or digitally with the on-board rotary switch and push-button.
The IFMA utilizes a seven position DIP switch, a rotary switch, a push-button and two indication LEDs to accomplish input circuit configuration, operational parameter set-up, and Input/Output indication.
The input circuitry is DIP switch selectable for a variety of sources.
Features- Simple on-line range setting
- User settable full scale frequency from 1 Hz to 25 kHz
- Four output operating ranges (0-5 V, 0-10 V, 0-20 mA, and 4-20 mA)
- Programmable input circuit accepts outputs from a variety of sensors
- 85-250 Vac and 9-32 Vdc powered versions available
- Low frequency cut-out and over range indication
- 3-Way electrical isolation
- Input and output indication LEDs
Specifications
Brand
Accuracy
- ± 0.1 % of Full Scale Range
- ± 0.2 % for 0-5 Vdc Range
Approvals & Certifications
- CE
- CSA C22.2 No. 14 (C,US)
- EMC Emissions: EN 50081-2 (Industrial Environment), CISPR 11 Radiated & Conducted Emissions, Immunity: EN 50082-2 (Industrial Environment), ENV 50140, 50141, EN 61000-4-2, 4, 8
- IECEE CB Scheme Test Report #97ME50135-042297, 61010-1, EN 61010-1
- UL File E137808, 508
Current
- Power Up Current: 600 mA for 50 ms, max.
Electrical Connectors
- Screw Typical Terminal Block
Enclosure, Body Material
- Plastic
Frequency
- Operating Frequency: 0 to 25 kHz
Humidity
- 85 % RH, Non-Condensing from 0° to 50° C
Indication
- LED
Input
- High Bias Input Trigger Level IH: 3 V
- High Bias Input Trigger Level IL: 2.5 V
- Low Bias Input Trigger Level IH: 0.75 V
- Low Bias Input Trigger Level IL: 0.25 V
Input Impedance
- 33 kΩ min. with the Sink & Source DIP Switches in the OFF Position
Input Signal
- ± 90 V
- 2.75 mA - Max.
Isolation
- Breakdown Voltage (Dielectric Withstand): 2,200 V between Power & Input, & Power & Output
- Breakdown Voltage (Dielectric Withstand): 500 V between Input & Output for 1 Minute
Mounting
- DIN Rail Mounting
Operating Temperature
- 0° to 50° C (32° to 122° F)
Output
- 0-10 Vdc at 10 mA - Max.
- 0-20 mA at 10 Vdc Min.
- 0-5 Vdc at 10 mA - Max.
- 10 V Across A Minuimum 1 Kiloohm Load (10 mA), Factory Calibrated for Loads greater than 1 MΩ
- 20 mA through A, Max.
- 4-20 mA at 10 Vdc Min.
Power
- 85-250 Vac, 48 to 62 Hz, 6.5 VA
- 9-32 Vdc, 2.5 W
- Sensor Power: (AC Version Only) +12 Vdc ± 25 % at 60 mA - Max.
Resistance
- Current Sinking: Internal 3.9 kΩ Pull-Up Resistor for Sensors with Current Sinking Output, max.
- Current Sourcing: Internal 1 kΩ Pull-Down Resistor for Sensors with Current Sourcing Output., max.
Resolution
- Current: 5 μA Min.
- Voltage: 3.5 mV Min.
Response Time
- 5 ms + 1 Period to 10 seconds + 1 Period
Shock
- 30 G, 11 ms in 3 Directions According to IEC 68-2-27
Storage Temperature
- -40° to 80° C (-40° to 176° F)
Vibration
- 5 G at 5 to 150 Hz in X, Y, Z Direction for 1.5 Hours According to IEC 68-2-6