Yodify Product Library
Add the ITL-101 Power Transmitter to your store or catalog
Book Your Demo and See How
or create your store
ITL-101 Power Transmitter
Brand: Infratek AGThe ITL-101 broad-band DC-50kHz Power Transmitters are available as single-phase, 2-phase (ARON), 3-phase and multi-phase versions (e.g. channel 1/2 in ARON, 0-20mA / 4-20mA output; channel 3 0-5V for DC-power output).
In addition to the standard current- and voltage ranges special ranges for current 10mA-20mA and voltage, 10V-600V, can be supplied. 3000Vac channel – and channel to output isolation results in maximum freedom for input connections.
The ITL-101 withstands fast common mode transients and can be used in frequency inverters and other electronically switched loads.
Available options are DC-100kHz, non-standard voltage range, non-standard current range, 40ms response output for process control, energy output (3600 pulses per hour for full scale), bipolar output to measure recuperated power, and single and three phase 0-100A current sensors.
Features- Suitable for DC, power lines, inverters
- 1-, 2-, 3-, and multi-phase
- Isolated channels each phase (3000V)
- DC-50kHz, Option DC-100kHz
- Fast response output for process control
- Outputs: ±20mA / ±5V / 4-20mA for power, 3600 pulses / hour for energy
- 0.2% accuracy
- Wide voltage range 10V – 600V
- Wide current range 10mA – 20A Extendable to 3000A
- Multi-phase: two outputs for power
- 85 – 264V AC supply
- 24V or 48V DC supply
Specifications
Brand
Standard Voltage Ranges Un
- ITL-101-1/3: 120 V, 250 V, working range: 0-150 %, DC-50 kHz
- ITL-101-2/4: 200 V, 400 V, working range: 0-150 %, DC-50 kHz
Standard Current Ranges In
- ITL-101-1/2/3/4: 1A, 2A, 5A, 10A, 20A, working range: 0-150 %, DC-50 kHz
Power Ranges
- ITL-101-1 : Un * In corresponds to 20 mA
- ITL-101-2 : 2x Un * In cos 60° corresponds to 20 mA
- ITL-101-3 : 3x Un * In corresponds to 20 mA
- ITL-101-4 : 2x Un * In cos 60° corresponds to 20 mA
- ITL-101-4 : 1x Un * In corresponds to 5 Vdc
Power Accuracy
- 40-400 Hz: 0.1 % Reading + 0.2 % Range (0.2 typical)
- 0< PF,1, DC, 400-1000 Hz: 0.3 % Reading + 0.2 %
- range, 0.7< PF< 1, 1 kHz: 1 % typical
Output
- 0-20 mA, 0-5 V , standard. Max. burden 500 Ω at 20 mA.
- 4-20 mA Option, bipolar output, option
Overload Continuous
- Voltage: 1.5 x Un, current: In< 10A, 3 x In, In = 20A, 1.5 x In
Overload 1 Second
- Voltage: 3 x Un, current: In< 10A, 5 x In, In = 20A, 2 x In
Input-Output isolation
- 3kV / 50 Hz / 1 minute
Temperature Range/- Coeffcient
- -10ºC to +50ºC, 0.002 % / deg. C
Supply
- 85-264 Vac (50 Hz/60 Hz), 3 VA, DC supply option
Case
- Light gray. Polycarbo / ABS case, wall mounting (M4 x 15, 85 x 50 mm)
- Support rail mounting (DIN EN 50022-35)
Size
- H x W x D = 70 x 100 x 115 mm, 400 gr.
- DC Measurements
- 50/60/400Hz Power Line
- Thyristor Controlled Loads
- Cycle Skipping
- Inverters