Anti-Ice Pressure Regulating Shut-Off Valve

Brand: Parker Hannifin

Parker Aerospace anti-ice pressure regulating shut-off valve controls the application of HP3 air to the downstream anti-ice pressure relief valve to maintain the engine intake (nacelle) free from ice under fault-free operation.
Features
  • Robust against high pressure and high temperature
  • Designed to withstand high-vibration levels
  • Chromed-bore surfaces coupled wit hcarbon bushings and seals for wear resistance

Specifications

Burst Pressure

  • Servo & Inlet: 1404 psia at Room Temperature

Dry Weight (Lbs)

  • 12.2 lbs Max.

External Leak Rate

  • 1.3 lbs/min

Internal Leak Rate

  • 2.23 lbs/min

Maximum Ambient Temperature (°F)

  • 1070° F Max.

Maximum Operating Temperature (°F)

  • 1016° F Duct Air Temperature, Max.

Maximum Working Pressure (psig)

  • 350 psia at 1016° F

Minimum Ambient Temperature (°F)

  • 395° F Duct Air Min. Operating

Minimum Operating Pressure (psig)

  • 17 psia at 395° F

Operating Temperature (°F)

  • 540° F Surrounding Air Temperature, Peak

Proof Pressure

  • Servo & Inlet: 655 psia at Room Temperature

Response Time

  • Opening, Regulating, & Closing: 6 seconds Each

Safety Factor

  • Spring-loaded Open Fail-safe Position