Brand: Yokogawa Electric CorporationThe absolute and gauge pressure transmitter model EJA510A and EJA530A can be used to measure liquid, gas, or steam pressure.
Both output a 4-20 mA DC signal corresponding to the measured pressure, and also feature remote setup and monitoring through communications with the BRAIN terminal and CENTUM CS or µXL or HART 275 host.
Features- 0.2% Accuracy (0.075% Option)
- 0.1% Stability for 1 year
- 8,500 psi MWP
Specifications
Metric Connection
- M20 x 1.5 Male DIN 16288
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber - Cover O-Rings
NPT Connection
- 1/2” NPT Female
- 1/2” NPT Male
Ambient Temperature Range
- -30° to 80° C (-22° to 176° F) with LCD Display
- -40° to 85° C (-40° to 185° F)
Pressure Type
- Absolute
Enclosure, Body Material
- 316 Cast Stainless Steel - Amplifier Housing
- ASTM CF-8M Stainless Steel - Amplifier Housing
- Low Copper Cast Aluminum Alloy
- SCS14A Stainless Steel - Amplifier Housing
Electrical Connectors
- 1/2” NPT Female
- Blind Plug
- G 1/2” Female
- M20 Female
- PG13.5 Female
Operating Temperature
- -20° to 80° C (-4° to 176° F)
Stability
- ± 0.1 % of URL Per 12 Months
Display
- LCD Display
Supply Pressure - Maximum
- psia: 1,450 (kPa: 10,000, bar: 100) - Capsule C
- psia: 29 (kPa: 200, bar: 2) - Capsule A
- psia: 290 (kPa: 2,000, bar: 20) - Capsule B
- psia: 7,200 (kPa: 50,000, bar: 500) - Capsule D
Cable Material
- Polyethylene Insulated PVC Sheathed
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.27 kPa
Temperature Effect
- ± (0.15 % of Span + 0.15 % of URL) Per 28° C (50° F) - Ambient Temperature Effects
Zero Offset
- External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
Diaphragm Material
- Hastelloy C-276
Load
- 0 to 1,335 ohms - for Operation
- 0.22 μF or Less - Load Capacitance
- 250 to 600 ohms - for Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- 304 Stainless Steel - Data Plate & Tag, Mounting Bracket
- SECC Carbon Steel
- SUS316 (316 Stainless Steel) - Data Plate & Tag, Mounting Bracket
Environmental Protection
- IP67
- NEMA 4X
Power Supply Effect
- ± 0.005 % Per Volt (21.6-32 Vdc, 350 ohms)
Enclosure Finish
- Epoxy Resin-Baked Coating
- Polyurethane Paint (Munsell 0.6 GY3.1/2.0)
Current
- 6,000 A, Max.
Process Connection Material
- Hastelloy C-276
- SUS316L (316L Stainless Steel)
Electrical Protection
- Lightning Protection
Damping Adjustment
- 0.1 to 64 seconds in 9 Increments
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART FSK Protocol
- PROFIBUS PA
Process Temperature
- -40° to 120° C (-40° to 248° F)
Output
- 3.8-20.5 mA
Output Signal
- 4-20 mA DC (2-Wire)
BSP Connection
- G 1/2” DIN 16 288 Male
Distance
- 6” (15 cm) or more - Spacing from Power Line
- Up to 2 Kilometers (1.25 Miles) when Using CEV - BRAIN Communication Distance
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276
Pressure Range
- bar: 0 to 500
- kPa: 0 to 50,000
- psi: 0 to 7,200
Approvals & Certifications
- Leak Test
- Mill Certificate
- Pressure Test
Supply Voltage
- 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive, or Non-sparking Typical
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - for General Use & Flameproof Typical
- 16.4 Vdc Min. - for Digital Communications, BRAIN & HART
- 24 Vdc Supply, 0 to 570 ohms Load
Overpressure & Static Pressure Limits
- psia: 2,900 (kPa: 20,000, bar: 200) - Capsule C, Max.
- psia: 580 (kPa: 4,000, bar: 40) - Capsule A & B, Max.
- psia: 8,500 (kPa: 60,000, bar: 600) - Capsule D, Max.
Vibration Effect
- ± 0.1 % of URL (5 to 15 Hz, 4 mm Peak-to-Peak Constant Displacement, 15 to 150 Hz, 2 G, 150 to 2,000 Hz, 1 G)
Drain, Vent Valves & Plug
- 316 Stainless Steel
Input Impedance
- 10 kiloohms or more at 2.4 kHz - for Communicating Device
NACE & NIST
- NACE MR-0175
Humidity
- 5 to 100 % Relative Humidity at 40° C (104° F) - Ambient Humidity
Alarm
- Down-Scale: -2.5 %, 3.6 mA DC or Less
- Down-Scale: -5 %, 3.2 mA DC or Less - Failure Alarm
- Up-scale: 110 %, 21.6 mA DC or more (Standard) - Failure Alarm
Mounting
- 2” (50.8 mm) Pipe
Response Time
- 0.3 second, Max.
Update Time
- 0.125 second
Approvals & Certifications
- ATEX Flameproof
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A, EN 61326-2-3
- FM Explosion-proof & Intrinsically Safe Approval
- IEC Ex Intrinsically Safe, Typical N & Flameproof Approval
- NAMUR NE43
- PED 97/23/EC
Accuracy
- ± 0.2 % of Span (Including the Effects of Zero-based Linearity, Hysteresis & Repeatability, Values are in Absolute)
Fill Material
- Fluorinated Oil
- Silicone
Documentation
Data Sheets
- EJA Series Fieldbus Communication pdf 939 KB
- EJA Series HART Protocol pdf 363 KB
- EJA Series NEPSI Certification [Option code: /NS2 and /NF2 ] pdf 61 KB
- EJA Series PROFIBUS PA Communication pdf 930 KB
- EJA Series With HART® Communication Differential Pressure Transmitter pdf 1,000 KB
- EJA510A and EJA530A Absolute and Gauge Pressure Transmitters pdf 1.5 MB
Manual
- EJA Series Differential Pressure and Pressure Transmitters Installation Manual *See Manual Change 15-009 16-004 16-018 pdf 4.8 MB
- EJA Series Fieldbus Communication Type *See Manual Change 10-007 12-004 16-004 pdf 1.4 MB
- EJA Series PROFIBUS PA Communication Type *See Manual Change 10-007 12-004 16-004 pdf 5.2 MB
- EJA510A and EJA530A Absolute Pressure and Gauge Pressure Transmitters [Style: S2] *See Manual Change 16-004 16-018 pdf 5.1 MB
- Manual Change 10-007 12-004 16-004 pdf 293 KB
- Manual Change 16-004 16-018 pdf 232 KB