Yodify Product Library
Instantly add the PR-43-GC General Type Compact Process Refractometer and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

PR-43-GC General Type Compact Process Refractometer

Brand: K-Patents Process Instruments

The K-Patents General type refractometer PR-43-GC system consists of a compact refractometer and a graphical user interface. 

The refractometer is a stand-alone device capable of operating independently. It has a measurement range of 0 to 100 % and it provides an Ethernet or 4–20 mA output signal proportional to the temperature-compensated concentration value for real-time process control. Different user interface options range from a rugged, multichannel, industrial computer to a compact light-weight and a web-based version, and allow the user to select the most preferred way to access and use the refractometer measurement and diagnostics data.

K-Patents Process refractometer PR-43-GC is an ideal all-round instrument for measuring the concentrations of a wide range of chemicals and other liquids in industrial applications. 

K-Patents Process refractometer PR-43-GC is designed for harsh environments that can be corrosive, abrasive, subject to extreme temperatures, pressures, vibration or contamination, humidity and dust, or any combinations of these factors. It is installed in the main processing line, bypass line or vessel either directly with Flange or Sandvik L coupling process connection, or via a large variety of cost-effective and easy to mount flow cell options. The user interface of the refractometer can be installed locally in the field, remotely in the control room or in both locations by connecting several user interfaces in a network.

Specifications

Accuracy

  • Across the Full Range of 0-100 %: Refractive Index ND ± 0.0002 Typically to ± 0.1 % by Weight

Ambient Temperature Range

  • Multi-Channel & Compact User Interface MI, CI: 0° to 50° C (32° to 122° F)
  • Refractometer: -40° to 45° C (-40° to 113° F)

Calibration

  • With NIST Traceable Cargille Standard R.I. Liquids over Full Range

Current Output

  • Galvanic Isolation 1,000 Vdc or AC (Peak), Hold Function During Prism Wash
  • Isolated 4-20 mA - Max.

Digital Measurement

  • 3648 Pixel CCD Element

Enclosure

  • Compact User Interface CI: Light-Weight Aluminum Enclosure for Control Room Conditions, Epoxy Coated IP66, Typical 4X Enclosure with Polycarbonate Display Shield for Field Conditions
  • Multi-Channel User Interface MI: Environmentally Sealed 316 Stainless Steel IP67 (Door Closed), IP66 (Door Open) / Typical 4X for Demanding Field & Outdoor Conditions

Instrument Verification

  • With NIST Traceable Cargille Standard R.I. Liquids & Guided Procedure, Including A Printable Verification Report

Interconnecting Cable Length

  • 10 metres (Standard), Field-Adjustable with a Platform 4 Cable Extender for up to 100 metres

Light Source

  • Sodium D-Line Light Emitting Diode (LED)

Patented Core-Optics

  • No Mechanical Adjustments

Power Supply

  • Compact User Interface CI: 24 Vdc ± 10 %, 8.5 W, Max.
  • Multi-Channel User Interface MI: 24 Vdc, 60 W
  • Multi-Channel User Interface MI: AC Input 100-240 Vac / 50/60 Hz, 60 W
  • Refractometer: 24 Vdc ± 10 %, Max.

Process Connection

  • Pipe Flow Cell Process Connection with ANSI 150 lbs, DIN PN 25 or JIS 10K
  • Sandvik Coupling L 2” (60.3 mm) for Pipe Size of 2”
  • Sandvik Coupling L 2.5” (76.1 mm) for Pipe Sizes of 2.5” & Larger
  • Via Pipe Flow Cell PFC for Pipe Line Size of 1”
  • Via Reducing Ferrule PR-9285 for Pipe Size of 1.5”
  • Via Wafer Flow Cell WFC for Pipe Sizes of 0.5”, 1” or 1.5”
  • Wafer Flow Cell Body Mounts between ANSI 150 lbs, DIN PN 25 or JIS

Process Pressure

  • Sandvik Coupling L 2” (60.3 mm) psi: 0 to 580 (kPa: 0 to 4,000, bar: 0 to 40) at 20° C (70° F)
  • Sandvik Coupling L 2.5” (76.1 mm) psi: 0 to 350 (kPa: 0 to 2,500, bar: 0 to 25) at 20° C (70° F)

Process Temperature

  • -40° to 130° C (-40° to 266° F)

Process Wetted Parts

  • AISI 316L Stainless Steel
  • Alloy 20 or Incoloy
  • Hastelloy C-276 / ASTM C-276
  • Nickel 200/201
  • Prism Gasket Modified PTFE
  • Prism Sapphire
  • Titanium GR2 / ASTM B348 GR2

Refractive Index Range

  • Full Range, ND=1.3200 to 1.5300 (Corresponds to Hot Water to 100 % by Weight) (Standard)
  • nD = 1.260 to 1.470
  • nD = 1.410 to 1.620
  • nD = 1.520 to 1.730

Refractometer Protection Class

  • IP67
  • Typical 4X (For Outdoor Use)

Remote & Ethernet Connection

  • 10/100Base-T Ethernet
  • UDP/IP Protocol Connection for Data Acquisition
  • Web Server for Configuration & Diagnostics

Repeatability

  • Across the Full Range of 0-100 %: ND ± 0.00004 (Typically Corresponds to ± 0.02 % by Weight)

Speed of Response

  • 1 second Undamped, Damping Time Selectable up to 5 minutes

Temperature Compensation

  • Automatic, Digital Compensation

Temperature Sensor

  • Built-In Pt-1000, Linearization According to IEC 751

User Interface Models

  • Compact User Interface CI
  • Multi-Channel User Interface MI
  • Web User Interface WI