Yodify Product Library
Instantly add the UltraPro 500 Ultrasonic Level Sensor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

UltraPro 500 Ultrasonic Level Sensor

Brand: Icon Process Control

The UltraPro Ultrasonic level Sensors are 2-Wire loop powered sensors designed provide reliable accurate level measurement, flow monitoring, and volume of liquid in tanks, pits, sumps and open channels.

The UltraPro series are very reliable and offer both 4-20mA analog output with HART® protocol or output RS-485 Modbus.

The UltraPro Series are designed to work with most types of remote instrumentation and provide enhanced functionality such as remote displays and remote monitoring solutions.
Features
  • Push Button Programming
  • Narrow Beam Technology
  • General Purpose | XP Explosion Proof
  • 2 Wire (4-20 mA) + (HART) Output Signal
  • Measuring Range: 4″ - 66 Ft
  • Accuracy: 0.2%

1 - 5 of 5 Part Numbers
UPS-500-01
UPS-500-01
UltraPro 500 Ultrasonic Level Sensor
  • Range: 1 m | 3.3 ft
  • Connection: ¾" Threaded
UPS-500-02
UPS-500-02
UltraPro 500 Ultrasonic Level Sensor
  • Range: 2 m | 6.6 ft
  • Connection: 1" Threaded
UPS-500-06
UPS-500-06
UltraPro 500 Ultrasonic Level Sensor
  • Range: 6 m | 19.7 ft
  • Connection: 1½" Threaded
UPS-500-10
UPS-500-10
UltraPro 500 Ultrasonic Level Sensor
  • Range: 10 m | 32.8 ft
  • Connection: 2¼" Threaded
UPS-500-20
UPS-500-20
UltraPro 500 Ultrasonic Level Sensor
  • Range: 20 m | 65.6 ft
  • Connection: 3" Flanged
1 - 5 of 5 Part Numbers

Specifications

Operating Range

  • 0.1 to 65 ft (0.03 to 20 m)

Working Frequency

  • 4-20 mA

Resolution

  • < 1 mm | 0.04”

Accuracy

  • 1 m | 0.2 % || 2 m | 0.15 % || 6 m | 0.15 % || 10 m | 0.2 % || 20 m | 0.2 %

Temperature Error

  • Maximum 0.04 % | K

Maximum Overpressure

  • 0.1 MPa

Beam Width

  • Size Dependant

Measuring Period

  • 1 m (0.5 s), 2 m (0.5 s), 6 m (1.2 s), 10 m (1.2 s), 20 m (5 s)

Maximum Current Output Load

  • @ U = 24 Vdc Rmax = 270 Ω | @ U = 22 Vdc Rmax = 180 Ω | @ U=20 Vdc Rmax = 90 Ω

Delay Between Rise Time

  • 1 m (5 s), 2 m (5 s), 6 m (5 s), 10 m (9 s), 20 m (9 s)

Minimum Voltage Load

  • Rmin > 1k Ohm

Enclosure Rating

  • NEMA 4X | IP67

Materials

  • Sensor Body: PVDF
  • O-Rings: FKM
  • Housing: ABS

Electrical

  • Output: 4-20 mA (Limit values 3.9 - 20.5 mA), HART RS-485 with protocol Modbus RTU
  • Supply Voltage: 18 to 36 Vdc ± 10 % regulated
  • Supply Voltage: 4-20 mA | Max. 22 mA (0-10 V - limit values 0 -10.2 V)

Operating Temperature

  • PVDF: -22° F to 158° F (-30° C to 70° C)
  • ABS: 32° F to 140° F (0° C to 60° C)

Standards & Approvals

  • CE
  • FCC
  • RoHS Compliant

  • Chemical Storage Tanks
  • Waste Sumps
  • Bulk Storage
  • Tanker Truck
  • Day Tank
  • Process Tank
  • Neutralization Tank
  • Open Channel
  • Chemical Feed and Clarifier Applications
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more