Yodify Product Library
Add the Model 265 Low Differential Pressure Transducer to your store or catalog
Book Your Demo and See How
or create your store
Model 265 Low Differential Pressure Transducer
Brand: Setra Systems, IncSetra’s Model 265 is a lower price solution that offers an excellent price to performance ratio and meets the requirements in all typical HVAC applications.
The 265 is a low differential pressure transducer that uses a dead-ended capacitive sensing element that requires minimal amplification and delivers excellent accuracy and longterm stability.
It delivers ±0.25%, ±0.4% and ±1% Full Scale accuracy options with pressure ranges from 0.25” W.C. up to 100” W.C. The 265 has a small footprint, an AC power option and an optional conduit cover that allows for simple, secure installation for any applications.
Features- Voltage or Analog outputs
- Reverse wiring protection
- Internal regulation
Specifications
Brand
Accuracy
- ± 0.1 % of Full Scale - Warm-Up Shift
- ± 0.25 % of Full Scale RSS
- ± 0.4 % of Full Scale RSS
- ± 1 % of Full Scale RSS
Applications
- Energy Management Systems
- Environmental Pollution Control
- HVac Systems
- Static Duct & Cleanroom Pressures
- Variable Air Volume & Fan Control
Approvals & Certifications
- CE
- UL 94
Compensated Temperature
- -18° to 65° C (0° to 150° F)
Electrical Connectors
- 1/2" Conduit
- 2-Wire - Circuit
- 3-Wire - Circuit
- Screw Terminal Strip
Enclosure, Body Material
- Fire Retardent Glass-Filled Polyester
Excitation Voltage
- 12-30 Vdc
- 24 Vac
- 24 Vdc
- 9-30 Vdc
Hysteresis
- 0.10 % of Full Scale
Load
- 0 to 800 ohms - External Load
Media
- Non-Conductive Gases
- Typically Air
Non-Linearity
- ± 0.22 % of Full Scale, BFSL
- ± 0.38 % of Full Scale, BFSL
- ± 0.98 % of Full Scale, BFSL
Non-Repeatability
- 0.05 % of Full Scale
Operating Temperature
- -18° to 65° C (0° to 150° F)
Output
- 0-10 Vdc
- 12 mA - Bi-Directional Output at Zero Pressure
- 2.5 Vdc (± 50 mV) - Bi-Directional Output at Zero Pressure
- 4-20 mA
Output Impedence
- < 100 ohms
Overpressure & Static Pressure Limits
- psi: 0 to 10 (kPa: 0 to 68.95, bar: 0 to 0.689)
Pressure Range
- inH₂O: 0 to 100
Span & Zero Effect
- ± 0.033 % of Full Scale/50° C (100° F)
- ± 0.06 % of Full Scale/50° C (100° F)
Stability
- 0.5 % of Full Scale/YR - Long Term Stability
Static Pressure
- psi: 10 (kPa: 69, bar: 0.69) - Max.
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Supply Voltage
- 30 Vdc + 0.004 x (Resistance of Receiver Plus Line) - Max.
- 9 Vdc + 0.02 x (Resistance of Receiver Plus Line) - Min.
Zero Offset
- 0.14 % of Full Scale/G
- 0.22 % of Full Scale/G
- 0.5 % of Full Scale/G