Brand: R. STAHL AG9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors.
The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card.
The auxiliary power, output and intrinsically safe input are galvanically separated.
Features- Ex i resistance isolator for Pt100 or Pt1000
- world's only two-channel device requiring just 8.8 mm of space per channel
- for two-, three- and four-conductor connection
1 - 10 of 10 Part Numbers
-235
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/10-77-11s
- Title Product Variant Technical Data - 9180/10-77-11s resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm2 flexible 0.25-2.5 mm2 flexible core end sleeve 0.2-2.5 mm2 rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160491
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/10-77-11s
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160492
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/10-77-11k
- Title Product Variant Technical Data - 9180/10-77-11k resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160494
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 37.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.89 W
- Power dissipation max. - 0.89 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/20-77-11s
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.180 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160495
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 37.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.89 W
- Power dissipation max. - 0.89 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/20-77-11k
- Title Product Variant Technical Data - 9180/20-77-11k resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.180 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160499
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 3910 Ω
- Measuring range min. - 180 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/11-77-11s
- Title Product Variant Technical Data - 9180/11-77-11s Resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 1000
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.1000 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160500
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 3910 Ω
- Measuring range min. - 180 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/11-77-11k
- Title Product Variant Technical Data - 9180/11-77-11k Resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 1000
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.1000 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160502
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 37.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.89 W
- Power dissipation max. - 0.89 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 3910 Ω
- Measuring range min. - 180 Ω
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/21-77-11s
- Title Product Variant Technical Data - 9180/21-77-11s Resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 1000
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.1000 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.180 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160503
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 37.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.89 W
- Power dissipation max. - 0.89 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 3910 Ω
- Measuring range min. - 180 Ω
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/21-77-11k
- Title Product Variant Technical Data - 9180/21-77-11k Resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 1000
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.1000 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.180 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
235
Ex i resistance isolator for Pt100 or Pt1000
world's only two-channel device requiring just 8.8 mm of space per channel
for two-, three- and four-conductor connection
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Relative humidity max. - < 85% at Ta > 40 °C
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 27.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 0.65 W
- Power dissipation max. - 0.60 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Measuring range max. - 391 Ω
- Measuring range min. - 18 Ω
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 05 ATEX E 176 X
- ATEX gas certificate - BVS 05 ATEX E 176 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 10.0055 X
- IECEX gas certificate - IECEx BVS 10.0055 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9180 series Ex i resistance isolators can be used for the intrinsically safe operation of Pt100 or Pt1000 resistance temperature detectors. The resistance measured at the input is transmitted to the output and can thereby be measured by an I/O card. The auxiliary power, output and intrinsically safe input are galvanically separated.
- Highlights - Ex i resistance isolator for Pt100 or Pt1000 world's only two-channel device requiring just 8.8 mm of space per channel for two-, three- and four-conductor connection
- Product Description - Resistance isolator Ex i field circuit ISpac
- Product Type - 9180/10-77-11s
- Title Product Variant Technical Data - 9180/10-77-11s resistance isolator
- WebCode - 9180A
Input
- Input - 2-, 3- and 4-wire circuits
- Input for resistance temperature detector - Pt 100
- Input resistance - ≤ 5 ohms (2-wire circuit)
- Medium resolution input - 0.0100 Ω
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm2 flexible 0.25-2.5 mm2 flexible core end sleeve 0.2-2.5 mm2 rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.160 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- output signal - Equal to input signal (resistor)
- Response time output - < 1 s
- Settling time output - < 10 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 16.4 mA
- Max. Power P o - 27.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
1 - 10 of 10 Part Numbers