Yodify Product Library
Add the GX90YD Digital Output Module to your store or catalog  
Book Your Demo and See How
or create your store

Decades of Yokogawa's innovative measuring technology has resulted in a flexible data logger that offers both reliability and ease of use.
Features
  • Output format: relay contact (C contact)
  • Rated load voltage: 30 Vdc or 250 Vac or less
  • Maximum load current: 3 A (DC) / 3 A (AC), resistive load, each
  • Minimum load voltage/current: 5 Vdc / 10 mA
  • Number of common: 6 (all outputs independent)

Specifications

Ambient Temperature Range

  • -20° to 60° C (-4° to 140° F)

Approvals & Certifications

  • CE
  • CSA
  • EMC Directive: EN 61326-1 Class A, EN 61000-3-2, EN 61000-3-3, EN 55011 Class A Group 1
  • GOST
  • KC
  • NRTL
  • UL

Channels

  • 6

Communication

  • Bluetooth
  • DARWIN
  • Ethernet - 10Base-T/100Base-TX Port
  • EtherNet/IP
  • Modbus RTU
  • Modbus TCP/IP
  • RS-422, RS-485
  • Serial Communication Port
  • SSL
  • USB 2.0

Current

  • 3 A (AC/DC) - Max.

Display

  • 7-Segment LED

Electrical Connectors

  • M3 Screw Terminal

Electrical Contacts

  • Normally Closed
  • Normally Open

Frequency

  • 50/60 Hz ± 1 %

Humidity

  • 20 to 85 % RH, Non-Condensing - Ambient Humidity

Input

  • 0.32 to 5.2 V to Standard Signal
  • 0-20 mA DC
  • -200 mV to 50 V - DCV
  • 4-20 mA DC - Standard Signal

Insulation Resistance

  • 20 MΩ or greater at 500 Vdc between Output Terminals & Internal Circuitry

Load

  • 5 Vdc / 10 mA Min. - Load Voltage/Current

Measurement Accuracy

  • DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
  • DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
  • ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
  • ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
  • ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
  • ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (0.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
  • ± 1.1° C (± 1.98° F) - R Thermocouple

Mounting

  • Clamp Terminal
  • DIN Rail
  • Wall Mounted

Output Format

  • Relay Contact (C Contact)

RTD Type

  • Cu10
  • Cu100
  • Cu25
  • Cu50
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt200
  • Pt25
  • Pt46
  • Pt50

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Shock

  • When On, 98 m/sec² or Less, 11 ms, 3 times in 6 directions (± X, ± Y, ± Z)

Supply Voltage

  • 180-264 Vac
  • 3,000 Vac, 1 Minute between Output Terminals & Internal Circuitry - Withstand Voltage
  • 30 Vdc or 250 Vac or Less - Rated Load Voltage
  • 90-132 Vac

Switch Type

  • SPDT, Relay

Temperature Range

  • -200° to 850° C (-328° to 1,562° F) - RTD
  • -270° to 2,320° C (-454° to 4,208° F) - Thermocouples

Update Time

  • 30 minutes - Warm-Up Time

Vibration

  • 5 ≤ F < 8.4 Hz Amplitude 3.5 mm Peak
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more