Brand: R. STAHL AGThe bushings are permitted to be used as current feeders in enclosures with type of protection āflameproofā.
They are fitted puncture-proof and insulated into the enclosure wall.
Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit.
For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid.
The bushings have to be secured against self-loosening.
Features- Means of supplying power to lead-in for Ex d enclosures
- Sealed to prevent propagation of flame on explosion and insulated from wall
- Versions with: split post connection, clamp connection, soldered connection
- For voltages up to max. 1000 V and currents up to max. 630 A
1 - 12 of 16 Part Numbers
139144
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 10.000 A
- Rated operational voltage AC - 400.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/20-ZL-C147
- Title Product Variant Technical Data - 8171/20-ZL-C147 20 pcs. post type bushin
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Soldered connection
- Connecting terminal Ex e - Cheese head screw
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Copper
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1
- Thread size - M10
- Weight - 0.116 kg
- Width across flats - A/F 14
Mounting / Installation
- Tightening torque - 8.00 N/m
139159
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 26.000 A
- Rated operational voltage AC - 400.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/17-AL-C795
- Title Product Variant Technical Data - 8171/17-AL-C795 Post type bushing 400V
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Soldered connection
- Connecting terminal Ex e - Hexagon screw
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Copper
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M15
- Weight - 0.225 kg
- Width across flats - A/F 17
Mounting / Installation
- Tightening torque - 15.00 N/m
139165
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 17.000 A
- Rated operational voltage AC - 400.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/06-RL-C1122
- Title Product Variant Technical Data - 8171/06-RL-C1122 Post type bushing 400V
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Soldered connection
- Connecting terminal Ex e - Sheath terminal
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Copper
- Moulding material - Epoxy resin
- Number of bolts - 6
- Thread pitch - 1,5
- Thread size - M42
- Width across flats - A/F 46
Mounting / Installation
- Tightening torque - 50.00 N/m
139166
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 26.000 A
- Rated operational voltage AC - 400.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/17-AL-C1154
- Title Product Variant Technical Data - 8171/17-AL-C1154 type bushing 400V CuZn
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Soldered connection
- Connecting terminal Ex e - Hexagon screw
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M15
- Weight - 0.225 kg
- Width across flats - A/F 17
Mounting / Installation
- Tightening torque - 15.00 N/m
242657
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 10.000 A
- Rated operational voltage AC - 400.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/20-ZL
- Title Product Variant Technical Data - 8171/20-ZL Bushing 400V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Soldered connection
- Connecting terminal Ex e - Cheese head screw
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1
- Thread size - M10
- Width across flats - A/F 14
Mounting / Installation
- Tightening torque - 8.00 N/m
242693
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 120.000 A
- Rated operational voltage AC - 800.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/48-AB
- Title Product Variant Technical Data - 8171/48-AB Bushing 800V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Cheese head screw
- Connecting terminal Ex e - Hexagon screw
- Connection cross-section - 16.0 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M20
- Width across flats - A/F 22
Mounting / Installation
- Tightening torque - 40.00 N/m
242888
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 54.000 A
- Rated operational voltage AC - 630.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/03-KK
- Title Product Variant Technical Data - 8171/01-KK Bushing 630V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Clamp connection with slit-bolt
- Connecting terminal Ex e - Clamp connection with slit-bolt
- Connection cross-section - 2.5 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M15
- Width across flats - A/F 17
Mounting / Installation
- Tightening torque - 15.00 N/m
242893
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 54.000 A
- Rated operational voltage AC - 800.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/43-AB
- Title Product Variant Technical Data - 8171/43-AB Bushing 800V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Cheese head screw
- Connecting terminal Ex e - Hexagon screw
- Connection cross-section - 6.0 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M15
- Width across flats - A/F 17
Mounting / Installation
- Tightening torque - 15.00 N/m
242894
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 200.000 A
- Rated operational voltage AC - 1000.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/51-CB
- Title Product Variant Technical Data - 8171/51-CB Bushing 1000V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Cheese head screw
- Connecting terminal Ex e - Round terminal
- Connection cross-section - 70.0 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M42
- Width across flats - A/F 46
Mounting / Installation
- Tightening torque - 50.00 N/m
242895
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 250.000 A
- Rated operational voltage AC - 1000.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/07-KB
- Title Product Variant Technical Data - 8171/07-KB Bushing 1000V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Cheese head screw
- Connecting terminal Ex e - Clamp connection with slit-bolt
- Connection cross-section - 25.0 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M42
- Width across flats - A/F 46
Mounting / Installation
- Tightening torque - 50.00 N/m
242957
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 250.000 A
- Rated operational voltage AC - 1000.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/56-DB
- Title Product Variant Technical Data - 8171/56-DB Bushing 1000V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Cheese head screw
- Connecting terminal Ex e - Clamp
- Connecting terminal Ex e 2 - For cable lug
- Connection cross-section - 150.0 mm²
- Material feedthrough bolt - Copper
- Moulding material - Epoxy resin
- Number of bolts - 1
- Thread pitch - 1,5
- Thread size - M42
- Width across flats - A/F 46
Mounting / Installation
- Tightening torque - 50.00 N/m
242958
Means of supplying power to lead-in for Ex d enclosures
Sealed to prevent propagation of flame on explosion and insulated from wall
Versions with: split post connection, clamp connection, soldered connection
For voltages up to max. 1000 V and currents up to max. 630 A
Ambient Conditions
- Ambient temperature - -55 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -55 °C
Electrical Data
- Ex version - Yes
- Rated operational current - 54.000 A
- Rated operational voltage AC - 500.00 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 00 ATEX 1066 U
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex de IIC Gb
- Gas explosion protection IECEx - Ex de IIC Gb
- IECEX gas certificate - IECEx PTB 06.0080U
General
- Functional Description - The bushings are permitted to be used as current feeders in enclosures with type of protection ”flameproof”. They are fitted puncture-proof and insulated into the enclosure wall. Duct bolt is located in the middle of a ring nut and the parts are bonded with a high-quality, track resistant insulating material (epoxy resin) to form an inseparable unit. For the connection points in the Ex e enclosure increased creepage paths and air gaps according to IEC/EN 60079-7 are valid. The bushings have to be secured against self-loosening.
- Highlights - Means of supplying power to lead-in for Ex d enclosures Sealed to prevent propagation of flame on explosion and insulated from wall Versions with: split post connection, clamp connection, soldered connection For voltages up to max. 1000 V and currents up to max. 630 A
- Product Description - Post-type bushing
- Product Type - 8171/14-RR
- Title Product Variant Technical Data - 8171/14-RR Bushing 500V calc.
- WebCode - 8171A
Mechanical Data
- Connecting terminal Ex d - Sheath terminal
- Connecting terminal Ex e - Sheath terminal
- Connection cross-section - 4.0 mm²
- Material feedthrough bolt - Brass
- Moulding material - Epoxy resin
- Number of bolts - 4
- Thread pitch - 1,5
- Thread size - M42
- Width across flats - A/F 46
Mounting / Installation
- Tightening torque - 50.00 N/m
1 - 12 of 16 Part Numbers