Brand: Siemens AGThe TS-3 temperature sensor provides an input signal for temperature compensation of specific Siemens ultrasonic level controllers.
Temperature compensation is essential in applications where temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of the associated ultrasonic transducer, a signal representative of the sound medium’s ambient temperature is obtained.
The temperature sensor should not be mounted in direct sunlight.
Temperature compensation is essential in applications where temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of the associated ultrasonic transducer, a signal representative of the sound medium’s ambient temperature is obtained.
The temperature sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that do not have an integral temperature sensor.
It is also recommended in cases where the integral temperature sensor of the transducer cannot be used.
The following conditions are typical for use of the TS-3 sensor: where a fast reaction to temperature variations is required, where a flanged ultrasonic transducer is used, or where high temperatures are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1 temperature sensors.
Features- Chemically Resistant ETFE Enclosure
- Fast Response Time
- Approved For Use In Potentially Explosive Atmospheres
Specifications
Brand
Measuring Range
- -40° to +100° C (-40° to +212° F)
Response Time
- Forced circulation (temperature variation: 63 %): 55 s
- Flange, forced circulation: 90 s
- Natural convection: 150 s
Installation Instructions
- Mounted indoors/outdoors, but not exposed to direct sunlight
Pressure
- Maximum 4 bar (60 psi/400 kPa)
Material (Enclosure)
- ETFE
Cable Connection
- 2-core, 0.5 mm² (20 AWG)
- shielded
- silicone sheath
Process Connection
- 3/4” NPT [(Taper), ANSI/ASME B1.20.1]
- R 3/4” [(BSPT), EN 10226], totally encapsulated
Certificates & Approvals
- CE, IEC Ex, FM, CSA, ATEX
- For use in applications where temperature sensor measurement from transducer does not accurately represent vessel temperature.