UNICONT Loop Indicator
Brand: Nivelco Process Control Co.UNICONT series is the universally scalable process value indicator of NIVELCO for current loops, most of them without the need for power supply.
PLK-501 plug in display can be connected to the 2-wire transmitters with its DIN 43650 socket, such as NIPRESS pressure/level gauge and MicroTREK radar level transmitter.
The UNICONT PLK-501 has 4 digit LED display and both ordinary and ATEX certified versions are available.
The UNICONT PDF- units are digital, field process indicators with 6 digit LCD display as well as transmitters, converting Analog current to HART signal.
They are suitable for the use in hazardous areas in their ATEX certified EEx ia and EEx d versions. Models with HART converter require power supply.
Features- HART converter
- 4 or 6 digit display, scalable
- ATEX certified versions
Specifications
Ambient Temperature Range
- -25° to 60° C (-13° to 140° F)
- Without Display: -40° to 70° C (-40° to 158° F) - PDF-401-8 Ex, PDF-501-8 Ex 4-Wire Model
Approvals & Certifications
- ATEX - Ex II 2 G EEx ia IIC T6, Ex II G EEx d IIB T6, Ex II (1)2 G EEx ia IIC T4
- CE 0408
- ISO 9001
- UKAS
Class
- Electric Protection: Class III
Communication
- HART
Conduit Connection
- M20 x 1.5
Diameter
- Outer Diameter of the Cable: 0.23 to 0.47” (6 to 12 mm)
Display
- 4-Digit LED of 0.29” (7.6 mm) Height - PLK-501-2, PLK-501-6 EX Model
- 6-Digit LCD, Engineering Units & Bargraph
Electrical Connectors
- Conduit Wire Cross Section, Max.
- DIN 43650 - PLK-501-2, PLK-501-6 EX Model
Enclosure, Body Material
- Paint Coated Aluminum (AISI12)
- Plastic (VALOX 412)
Environmental Protection
- Explosion-proof
- IP65
- IP67
Input
- 0-20 mA - PDF-401-8 Ex, PDF-501-8 Ex 4-Wire Model
- 4-20 mA
Mounting
- Wall Mounting
Output
- 4-20 mA / HART - PDF-401-8 Ex, PDF-501-8 Ex 4-Wire Model
Power Supply
- 9-36 Vdc - PDF-401-8 Ex, PDF-501-8 Ex 4-Wire Model
Resistance
- Input: 150 ohms - PLK-501-2, PLK-501-6 Ex Model
Supply Voltage
- 9-36 Vdc
Voltage Drop
- 5.2-6.5 V, Max.
- Hazardous Areas
- Process Indicators