Series 607 Differential Pressure Transmitter

Brand: Dwyer Instruments, LLC

Series 607 Differential Pressure Transmitter combines very low ranges with exceptional stability, reliability and either ±0.25% or ±0.5% accuracy for the most demanding applications.

Ranges from 0-0.1" w.c. to 0-25" w.c. Ultra thin glass clad silicon diaphragm design resists shock and vibration, practically eliminates drift. 

Certification to NIST standards is included with each unit. Tough stainless steel housing is NEMA 2 rated to protect against moisture and dirt. Use with air and other compatible gases.
Features
  • High stability at low pressure ranges provides exceptional accuracy for insuring tight control and minimizing costly out of specification conditions
  • Provides sensitivity to pressure changes but resists vibration preventing drift and less accurate readings
  • Stainless steel housing meets standards for lab and clean room applications

1 - 12 of 36 Part Numbers
607-0
607-0
DWYER Differential Pressure Transmitter, Range 0-.10" W.C.
  • Pressure Range - Inches WC: 0 to 0.1
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - No Additional Certifications
607-0-NISTCAL-PT1
607-0-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to 0.1
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - NIST Traceable Calibration Certificate
607-01
607-01
  • Pressure Range - Inches WC: 0 to 0.1
  • Accuracy - ± 0.25% Full Scale Accuracy
  • Certificates - No Additional Certifications
607-01-NISTCAL-PT1
607-01-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to 0.1
  • Accuracy - ± 0.25% Full Scale Accuracy
  • Certificates - NIST Traceable Calibration Certificate
607-0B
607-0B
DWYER Differential Pressure Transmitter, Range .10-0-.10" W.C.
  • Pressure Range - Inches WC: 0 to ± 0.1
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - No Additional Certifications
607-0B-NISTCAL-PT1
607-0B-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to ± 0.1
  • Certificates - NIST Traceable Calibration Certificate
607-1
607-1
DWYER Differential Pressure Transmitter, Range 0-.25" W.C.
  • Pressure Range - Inches WC: 0 to 0.25
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - No Additional Certifications
607-1-NISTCAL-PT1
607-1-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to 0.25
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - NIST Traceable Calibration Certificate
607-11
607-11
  • Pressure Range - Inches WC: 0 to 0.25
  • Accuracy - ± 0.25% Full Scale Accuracy
  • Certificates - No Additional Certifications
607-11-NISTCAL-PT1
607-11-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to 0.25
  • Accuracy - ± 0.25% Full Scale Accuracy
  • Certificates - NIST Traceable Calibration Certificate
607-1B
607-1B
DWYER Differential Pressure Transmitter, Range .25-0-.25" W.C.
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Certificates - No Additional Certifications
607-1B-NISTCAL-PT1
607-1B-NISTCAL-PT1
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Accuracy - ± 0.5% Full Scale Accuracy
  • Certificates - NIST Traceable Calibration Certificate
1 - 12 of 36 Part Numbers

Specifications

Accuracy

  • ± 0.25 % of Full Scale
  • ± 0.5 % of Full Scale

Approvals & Certifications

  • CE

Compensated Temperature

  • 2° to 57° C (35° to 135° F)

Consumption

  • 3.6 mA (Min.)

Electrical Connectors

  • Screw Terminal

Enclosure, Body Material

  • 300 Stainless Steel

Environmental Protection

  • IP11
  • NEMA 2

Humidity

  • 10 to 95 % RH

Loop Resistance

  • 0 to 1045 ohms Vmin=12 V+[(.22 A)(RL)]

Media

  • Air
  • Non-Conductive, Non-Corrosive Gases

NACE & NIST

  • NIST Traceable Calibration Certificate

Output

  • 4-20 mA DC, 2-Wire

Power Requirement

  • 12-36 Vdc

Pressure Range

  • inH₂O: 0 to 25

Pressure Type

  • Differential

Process Connection Material

  • Barbed Stainless Steel for 3/16" I.D. Tubing

Response Time

  • 250 ms

Span & Zero Adjustments

  • ± 10 % of Full Scale Adjustment
  • Externally Accessible Potentiometers
  • Non-Interactive

Stability

  • ± 0.5 % of FSO/Year

Temperature Effect

  • ± 0.015 % of Full Scale/°F (Zero & Span)

Temperature Range

  • -29° to 71° C (-20° to 160° F)

Tube Connection

  • 3/16" Tube

  • Leak Detection
  • Clean Room Control
  • Lab and Fume Hood Pressure Control