Yodify Product Library
Instantly add the I/IS 404/414 Industat and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
I/IS 404/414 Industat
Brand: Trafag Sensors & ControlsSwiss based trafag is a leading international supplier of high quality sensors and monitoring instruments for the measurement of pressure and temperature.
Features- Compact design
- Rugged housing
- Protection IP65
- Any mounting position possible
Specifications
Accuracy
- ± 2 % of Full Scale - Typical
Ambient Temperature Range
- -30° to 70° C (-22° to 158° F)
Applications
- Ex Industrial Thermostat with Remote Sensor
Approvals & Certifications
- EN 60730-1, EN 60730-2-9
Capillary Length
- Capillary Length Tube: 0 to 5,000 mm
Electrical Connectors
- M20 x 1.5 / SW24
- Terminal Screw: 3 x 1 to 2.5 mm²
Electrical Rating
- 0.1 (0.1) A at 24 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
- 0.2 (0.02) A at 250 Vdc for Small Switching Differential, Not Adjustable
- 0.25 (0.03) A at 250 Vdc for Average Switching Differential, Not Adjustable
- 0.4 (0.03) A at 125 Vdc for Small Switching Differential, Not Adjustable
- 0.5 (0.05) A at 125 Vdc for Average Switching Differential, Not Adjustable
- 1 (1) A at 12 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
- 10 (0.75) A at 500 Vac for Average Switching Differential, Not Adjustable
- 10 (1.25) A at 250 Vac for Small Switching Differential, Not Adjustable
- 10 (1.5) A at 125 Vac for Small Switching Differential, Not Adjustable
- 15 (1.25) A at 250 Vac for Average Switching Differential, Not Adjustable
- 15 (1.5) A at 125 Vac for Average Switching Differential, Not Adjustable
- 15 (2.5) A at 14 Vdc for Small Switching Differential, Not Adjustable
- 2 (1) A at 30 Vdc for Small Switching Differential, Not Adjustable
- 2 (2) A at 5 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
- 6 (1.5) A at 30 Vdc for Average Switching Differential, Not Adjustable
Enclosure, Body Material
- Aluminum (ALSI9Cu3) Coated
Environmental Protection
- IP65
Fill Material
- Liquid
Humidity
- Maximum
Insulation Resistance
- > 2 megaohms
Measuring Range
- -30° to 350° C (-22° to 662° F)
Mounting Position
- Any Orientation
Repeatability
- ± 0.5 % of Full Scale
Sensor, Probe Material
- Sensor: Copper
- Sensor: Copper Nickel-Plated
- Sensor: Stainless Steel
Shock
- 50 G, 11 milliseconds
Storage Temperature
- -30° to 85° C (-22° to 185° F)
Vibration
- ± 1.6 mm (5 to 25 Hz)
- 4 G (25 to 100 Hz)
Voltage
- Dielectric Strength: 1.45 kV (U ≤ 250 V)
- Dielectric Strength: 2 kV (U ≤ 500 V)
- Railways
- Machine Tools