Yodify Product Library
Instantly add the 741-743 & 802 Level Switch and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

741-743 & 802 Level Switch

Brand: SOR Inc

Displacer controls offer alternative features to the float-operated control. The sensor is a weight (displacer), heavier than the liquid, that is suspended by a spring. 

When liquid contacts the displacer, a buoyancy force is produced, which causes the effective weight of the displacer to change. This causes the spring to retract slightly to a new equilibrium position. 

When the spring retracts, the attraction sleeve also moves upward into the field of the external magnet, thus overcoming the force of the bias spring and actuating the switching element. 

This principle provides for narrow or wide switching differential, and allows switching point alteration by moving the displacer(s) up or down the suspension cables. 

Displacers may be arranged in combinations of narrow and wide differential to operate up to three switching stages. 

Displacer controls operate under higher pressure conditions than float-operated switches.

Specifications

Brand

Approvals & Certifications

  • ATEX
  • CE
  • CRN
  • CSA
  • EAC
  • Ex
  • IECEX
  • RTN
  • UL

Approvals & Certifications

  • 61508 for Non-Redundant: SIL 1 & SIL 2 Safety Instrumented Systems
  • Certificate of Calibration
  • Certificate of Conformance (Power Piping, ASME 31.1, 31.3)
  • Compliance/Conformance
  • Dielectric Test
  • Dye Penetration Testing
  • Hydrostatic Pressure Test
  • Inspection Certificate
  • Insulation Resistance
  • Magnetic Particle Examination
  • Mill Certificate
  • QA Test Report
  • Radiograph Examination
  • Ultrasonic Examination

Conduit Connection

  • 1/2” NPT
  • 3/4” NPT
  • M20 x 1.5

Electrical Connectors

  • Electrical / Pneumatic Connection: 1” NPT
  • Electrical / Pneumatic Connection: 1/4” NPT
  • Electrical / Pneumatic Connection: M20 x 1.5 Adapter

Electrical Contacts

  • Gold Contact

Electrical Rating

  • 1-15 A at 110-250 Vac, Resistive/Inductive
  • 1-15 A at 20-250 Vdc, Resistive/Inductive

Enclosure Finish

  • Housing Exterior: Fungicidal Varnish
  • Powder Epoxy Coated

Enclosure, Body Material

  • Switch (Extended, Pneumatic): Cast Iron
  • Valve (3-Way), Switch (Extended, Pneumatic): Aluminum

Environmental Protection

  • IP66
  • NEMA 4
  • NEMA 4X

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#
  • 1-1/2” (DN 40) - 1500#
  • 1-1/2” (DN 40) - 300#
  • 1-1/2” (DN 40) - 600#

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150#
  • 1” (DN 25) - 1500#
  • 1” (DN 25) - 300#
  • 1” (DN 25) - 600#

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 1500#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - 600#

Flange Type

  • Raised Face (RF)
  • Ring Joint Facing

Fluid Specific Gravity

  • 0.41 to 0.57

Gasket Material

  • 316 Stainless Steel wound around Grafoil
  • Nitrile Binder Composite

Humidity

  • < 85 %, Max.

Materials of Construction

  • Attraction Sleeve Material: 400 Stainless Steel
  • Chamber, Float, Displacer, Attraction Sleeve Material: 316 Stainless Steel
  • Chamber, Float, Displacer, Attraction Sleeve Material: 316L Stainless Steel
  • Chamber, Float, Displacer, Attraction Sleeve Material: Carbon Steel (A106B)
  • Float, Displacer, Attraction Sleeve Material: Monel 400
  • M20 Adapter: Brass

NACE & NIST

  • NACE

Name Plate, Tag Material

  • Stainless Steel
  • Fiber

NPT Connection

  • 1” NPT
  • 1-1/2” NPT
  • 2” NPT

O-Ring Material

  • Buna-N

Operating Pressure

  • psi: 3,600 (kPa: 24,821, bar: 248.2) - Max.

Power

  • 100 mW

Process Connection Material

  • 304 Stainless Steel
  • 304L Stainless Steel
  • 316 Stainless Steel
  • 316L Stainless Steel
  • Alloy 20 or Incoloy
  • Carbon Steel (A333 GR.6, A335-P11 Chrome Moly, A335-P9)
  • Hastelloy C
  • Monel 400

Sensor, Probe Style

  • Float

Switch Type

  • DPDT
  • SPDT

Temperature Range

  • 649° C (1,200° F) - Max.

Trim Material

  • 316 Stainless Steel
  • 400 Series Stainless Steel

Welded Connection

  • 1” Socket Weld End
  • 1-1/2” Socket Weld End
  • 2” Socket Weld End

  • Indirect mount is required because tank cannot be easily shutdown for service
  • When turbulence is high enough to cause false readings/damage to the displacer
  • Flanged service connection for maintenance, cleaning, or troubleshooting
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more