pac-Carrier Series 9195
Brand: R. STAHL AGThe 9195 series pac carrier is a cost-effective solution allowing Ex i field devices to be connected to common I/O modules of distributed control systems and programmable logic controllers.
The extremely robust carrier is suitable for eight or 16 standard ISpac isolators and can process 32 signals, including a combination of Exi and non-Ex i signals. It can be adapted to accommodate new I/O modules at any time.
The carrier can be combined with the 9192 series HART Mux.
Features- Prefabricated system cables make it quick and easy to install – simply snaps onto a DIN rail or mounting plate
- Can be used with the Emerson Delta V, Schneider Foxboro/Tricon, Honeywell C300, Siemens ET200M and ET200F, YokogawaCentum VP and ProSafe-RS
- All ISpac isolators 91xx can be used in the pac carrier
1 - 2 of 2 Part Numbers
209268
Prefabricated system cables make it quick and easy to install – simply snaps onto a DIN rail or mounting plate
Can be used with the Emerson Delta V, Schneider Foxboro/Tricon, Honeywell C300, Siemens ET200M and ET200F,YokogawaCentum VP and ProSafe-RS
All ISpac isolators 91xx can be used in the pac carrier
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -20 °C
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Redundant supply - yes, decoupled with diodes
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Connection HART-multiplexer - Yes
- Connections - via HART multiplexer 9192
- Fuse - 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supply
- I/O type - Any
- Number of channels - 32
- Number of channels field device interface (HART) - 8,16, 32
- Redundancy - No
- Type of signal - DI, DO, AI, AO
Explosion Protection
- Application range (zones) - 2, 22
- ATEX gas certificate - BVS 03 ATEX E 213 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), SIL (exida), USA (FM)
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 10.0042 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - The 9195 series pac carrier is a cost-effective solution allowing Ex i field devices to be connected to common I/O modules of distributed control systems and programmable logic controllers. The extremely robust carrier is suitable for eight or 16 standard ISpac isolators and can process 32 signals, including a combination of Ex i and non-Ex i signals. It can be adapted to accommodate new I/O modules at any time. The carrier can be combined with the 9192 series HART Mux.
- Highlights - Prefabricated system cables make it quick and easy to install – simply snaps onto a DIN rail or mounting plate Can be used with the Emerson Delta V, Schneider Foxboro/Tricon, Honeywell C300, Siemens ET200M and ET200F, Yokogawa Centum VP and ProSafe-RS All ISpac isolators 91xx can be used in the pac carrier
- Product Description - pac-Carrier ISpac
- Product Type - 9195/16H-XX0-01C
- WebCode - 9195A
Input
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault
Mechanical Data
- Grid dimension - 17.60 mm
- Number of slots - 16
- Weight - 0.843 kg
Mounting / Installation
- Mounting orientation - horizontal or vertical
- Mounting position - vertical horizontal
- Mounting type - DIN rail or wall mounting
Output
- Application - Universal
- LFD relay - Yes
- Switching capacity fault message contact - 30 V / 100 mA
221918
Prefabricated system cables make it quick and easy to install – simply snaps onto a DIN rail or mounting plate
Can be used with the Emerson Delta V, Schneider Foxboro/Tricon, Honeywell C300, Siemens ET200M and ET200F,YokogawaCentum VP and ProSafe-RS
All ISpac isolators 91xx can be used in the pac carrier
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -20 °C
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Redundant supply - yes, decoupled with diodes
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Connection HART-multiplexer - No
- Connections - via connection of automation systems
- Fuse - 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supply
- I/O type - Any
- Number of channels - 32
- Number of channels field device interface (HART) - 8,16, 32
- Redundancy - No
- Type of signal - DI, DO, AI, AO
Explosion Protection
- Application range (zones) - 2, 22
- ATEX gas certificate - BVS 03 ATEX E 213 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), SIL (exida), USA (FM)
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 10.0042 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - The 9195 series pac carrier is a cost-effective solution allowing Ex i field devices to be connected to common I/O modules of distributed control systems and programmable logic controllers. The extremely robust carrier is suitable for eight or 16 standard ISpac isolators and can process 32 signals, including a combination of Ex i and non-Ex i signals. It can be adapted to accommodate new I/O modules at any time. The carrier can be combined with the 9192 series HART Mux.
- Highlights - Prefabricated system cables make it quick and easy to install – simply snaps onto a DIN rail or mounting plate Can be used with the Emerson Delta V, Schneider Foxboro/Tricon, Honeywell C300, Siemens ET200M and ET200F, Yokogawa Centum VP and ProSafe-RS All ISpac isolators 91xx can be used in the pac carrier
- Product Description - pac-Carrier ISpac
- Product Type - 9195/16A-XX0-03B3
- Title Product Variant Technical Data - 9195/16A-XX0-03B3 pac-carrier
- WebCode - 9195A
Input
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault
Mechanical Data
- Grid dimension - 17.60 mm
- Number of slots - 16
- Weight - 0.834 kg
Mounting / Installation
- Mounting orientation - horizontal or vertical
- Mounting position - vertical horizontal
- Mounting type - DIN rail or wall mounting
Output
- Application - Universal
- LFD relay - Yes
- Switching capacity fault message contact - 30 V / 100 mA
1 - 2 of 2 Part Numbers