Yodify Product Library
Instantly add the Emergency Luminaire for Fluorescent Lamps EXLUX Series 6409/5 and 50,000+ more product series to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

Emergency Luminaire for Fluorescent Lamps EXLUX Series 6409/5

Brand: R. STAHL AG

The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. 

If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
Features
  • Can be used in Ex Zones 2, 21 and 22
  • Weekly function test and annual emergency light duration test

1 - 12 of 18 Part Numbers
240868
240868
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9007-1611-7
  • Title Product Variant Technical Data - 6409/522-9007-1611-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.200 kg
  • Width - 183.500 mm
240870
240870
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9007-1622-7
  • Title Product Variant Technical Data - 6409/522-9007-1622-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.300 kg
  • Width - 183.500 mm
240871
240871
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9007-2611-7
  • Title Product Variant Technical Data - 6409/522-9007-2611-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.200 kg
  • Width - 183.500 mm
240872
240872
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9007-2622-7
  • Title Product Variant Technical Data - 6409/522-9007-2622-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.300 kg
  • Width - 183.500 mm
240876
240876
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9607-2611-7
  • Title Product Variant Technical Data - 6409/522-9607-2611-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.300 kg
  • Width - 183.500 mm
240877
240877
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/522-9607-2622-7
  • Title Product Variant Technical Data - 6409/522-9607-2622-7 emerg.light 18W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.400 kg
  • Width - 183.500 mm
240878
240878
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9007-1611-7
  • Title Product Variant Technical Data - 6409/542-9007-1611-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.500 kg
  • Width - 183.500 mm
240879
240879
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9007-1622-7
  • Title Product Variant Technical Data - 6409/542-9007-1622-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.600 kg
  • Width - 183.500 mm
240880
240880
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9007-2611-7
  • Title Product Variant Technical Data - 6409/542-9007-2611-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.500 kg
  • Width - 183.500 mm
240893
240893
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - without

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9007-2622-7
  • Title Product Variant Technical Data - 6409/542-9007-2622-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.600 kg
  • Width - 183.500 mm
240894
240894
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9607-1611-7
  • Title Product Variant Technical Data - 6409/542-9607-1611-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.700 kg
  • Width - 183.500 mm
240895
240895
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 2, 21 and 22

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043/792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x Stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - PTB 14 ATEX 2022
  • ATEX gas certificate - PTB 14 ATEX 2022
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 3 D Ex tc IIIC T80 °C Dc
  • Dust Explosion Protection ATEX 2 - II 3 D Ex tb IIIC Dc
  • Dust explosion protection IECEx - Ex tc IIIC T80 °C Dc
  • Dust explosion protection IECEx 2 - Ex tb IIIC Dc
  • Gas explosion protection ATEX - II 3 G Ex nA d mb IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA d mb IIC T4 Gc
  • IECEX dust certificate - IECEx PTB 14.0043
  • IECEX gas certificate - IECEx PTB 14.0043
  • Languages of the documentation - English, German, Russian
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - The 6409 Series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The external battery powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the luminaire or battery case is opened, the battery circuit is disconnected. The robust plastic enclosure of the luminaire is easy to open thanks to the practical central lock.
  • Highlights - Can be used in Ex Zones 2, 21 and 22 Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6409/542-9607-1622-7
  • Title Product Variant Technical Data - 6409/542-9607-1622-7 emerg.light 36W
  • WebCode - 6409A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.630 kg
  • Width - 183.500 mm
1 - 12 of 18 Part Numbers