Fluxus F704 TE Industrial Thermal Energy Meter

Brand: FLEXIM

Heat and Cold Metering in any Environment.

Non-invasive Thermal Energy Metering within Industrial Environments.

The FLUXUS F704 Thermal Energy is specially designed for heating and cooling Thermal Energy measurement, with all measurements – Flowmeter, Temperature, and BTU computer, contained in one device. 

Temperature and BTU calculations are done in accordance with EN 1434 Thermal Energy meter standard.

Like all measuring systems of the FLUXUS series, the F704 Thermal Energy measures the volumetric flow rate non-invasively via its clamp-on ultrasonic transducers. 

Simultaneously, temperature probes monitor the temperatures at the supply and return lines of the heating or cooling system - either non-invasively with clamp-on sensors or by use of insertion temperature probes.

From the temperature difference as well as the measured volume flow rate and on the basis of the physical media parameters (liquid enthalpy data stored in the meter), the heating or cooling performance is calculated.

Further, the FLUXUS F704 Thermal Energy can also be equipped with two measurement channels to:
  • Simultaneously measure two pipes e.g. chilled and hot water submetering in a building, two chillers at the chiller plant, etc.,
  • Allow for a complete monitoring of a chiller – chilled water and condenser water,
  • To allow accurate measurements even at locations that have very little straight run – dual mount on one pipe averages profile disturbance.
An important advantage of the FLUXUS F704 Thermal Energy lies with its very high zero point stability and unrivalled accuracy even at very low flow rates.

In submetering it is necessary to capture very low flow rates during off peak seasons – like hot water delivery to a building in the summer months – or this becomes free energy. 

Many meters have zero drift that is hidden by a zero cut-off setting, and some metering technologies just cannot measure the low velocities associated with Thermal Energy off peak flow rates.

Another important aspect of FLEXIM's BTU meter is that every meter is WET FLOW CALIBRATED in a NIST traceable and ISO 17025 accredited flow calibration laboratory. 

This is a true calibration not a certificate of a bench tested meter that others might supply as an accuracy certification. BTU meters are used for billing allocation; your BTU meters need solid documentation of accuracy.

A critical and sometimes overlooked aspect of the BTU meter combined performance is the temperature accuracy. 

Unmatched RTD’s can have a 1o F uncertainty on the temperature accuracy. 

For a chilled water system with a delta T of 10o F this can represent a 10% uncertainty (error) in measurement. 

FLEXIM RTD’s are 4-wire matched pair with an extremely high match of 0.03o F at 50° F (chilled water temperature). 

FLEXIM also adheres to EN 1434 for temperature accuracy for the full range of temperature measurement.

MAINTENANCE FREE metering is now the standard that FLEXIM has achieved. 

The first aspect of zero maintenance is that the sensors are not in contact with the liquid, there is nothing to get fouled up. 

The second aspect of zero maintenance is achieved by utilizing Flexim’s non grease transducer COUPLING PADS. 

These pads can handle temperatures up to 390o F. FLEXIM has a huge installed base (over 100 Universities and over 10,000 metering points), and a history since the 2006 implementation with the coupling pads of never having a transducer signal failure.
Features
  • High Accuracy 
  • Low installation cost 
  • No maintenance

Specifications

Brand

Available Hazardous Area Classification (Optional)

  • FM Class I, Div. 2

Communication Protocol

  • RS-485, Modbus RTU/TCP, BACNet MS/TP, M-Bus

Degree of Protection

  • Transmitter: IP65, Transducers: up to IP68

Flow Channels

  • 1 or 2

Flow Velocity Range

  • 0.03 to 80 ft/sec

Inputs Energy Version

  • Maximum

Measurement Accuracy (Field Calibrated)

  • Volume Flow: ± 0.5 % of Reading, ± 0.03 ft/sec

Measurement Accuracy (Standard)

  • Temperature: 0.03° F Match at 50° F, Full Scale as Per EN 1434
  • Volume Flow: ± 1 % of Reading, ± 0.03 ft/sec

Media Temperature

  • -40° to +266° F (Extended up to 392° F)

Medium

  • Any Liquid Heat Transfer Medium (with up to 10 % of Gaseous or Solid Entrainments)

Operating Temperature of the Transmitter

  • -40° to +140° F

Outputs Energy Version

  • (Switchable Active / Passive) Current, Voltage, Frequency, Binary

Pipe Diameter Range

  • 1” to 80” (no Limitations on Wall Thickness & Material)

Quantities of Measurement

  • Heat Quantity (BTU), (Volume Flow, Mass Flow, Flow Velocity)

Repeatability

  • Volume Flow: ± 0.15 % of Reading, ± 0,01 m/sec