Specifications
Density Ranges G/Litre
- 10
- 16
- 25
- 40
- 60
- 80
Pressure Range (Related to 20° C)
- 1.64 to 11.33 bar abs.
Over Pressure Safety bar Abs.
- 14
- 29
- 67
Burst Pressure of Sensor bar Abs.
- 17
- 35
- 80
Designed for Sensing
- Pure SF6 Gas
Principle
- piezoresistive
Pressure Reference
- absolute Pressure
Process Connection
- G 1/2 B Male (Other Connections on Request)
Materials
- Internal transmitting fluid: Synthetic oil
- Case, terminal Case: Aluminium
- Wetted Parts: Stainless Steel
Power Supply UB
- DC 10 ... 30 V
Signal Output & Maximum Load RA
- 4 ... 20 mA, 2-Wire, RA ≤ (UB - 10 V) / 0.02 A with RA in Ohm and UB in Volt
Accuracy
- -40° C: 3 % of Span, 20° C: 1 % of Span, 60° C: 2.3 % of Span (Optimal accuracy point)
- -40° C: 4 % of Span, 20° C: 2 % of Span, 60° C: 3.3 % of Span (Beginning and end of Measuring Range)
1-Year Stability
- ≤ 0.3 % of Span (At reference Conditions)
Nominal Temperature
- -40° to +60° C (-40° to +140° F) [gas phase!]
Storage Temperature
- -40° to +80° C (-40° to +176° F)
CE Conformity
- EN 61326-1
EMC Directive
- 2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (Industrial locations)
High Voltage Strength
- DC 750 V (wiring versus Case)
Electromagnetic Immunity (EMI) / RFI Per IEC 61000-4
- IEC 61000-4-2 (ESD): test level 4 (8 kV)
- IEC 61000-4-3 (Field): test level 3 (10 V/m)
- IEC 61000-4-4 (Burst): test level X (± 4 kV)
- IEC 61000-4-5 (Surge): test level 2 (± 1 kV)
- IEC 61000-4-6 (Conducted RFI): test level 3 (10 V)
Cable Gland
- Cable Gland M20 x 1.5
Electrical Connection
- Internal terminal Screws, cross section Max. 2.5 mm²
Wiring Protection
- Protected Against Reverse Polarity and Overvoltage
Ingress Protection
- IP65 per EN 60529 / IEC 529
Weight
- Approximately 0.75 kg
- Gas density monitoring of closed SF6 tanks
- For indoor and outdoor installation in SF6 gas-insulated switchgear
- Easily integrate able into a gas management system