Yodify Product Library
Instantly add the Platinum 2.5K Multi-Function Recorder and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Platinum 2.5K Multi-Function Recorder

Brand: RIS - Scientific Columbus

For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture while meeting regulatory compliance including PRC-002-2.

This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis.

All of these functions are performed at the highest level so it will meet your needs of today and the future.

In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.

The Platinum 2.5K takes place of several devices integrating their functions into one unit, saving you time and money.
Features
  • Very high-speed transient recorder-analyze switching transients, lightning strikes.
  • Transient fault recorder-post fault analysis to verify protection and circuit breaker operations, fault clearance times
  • Disturbance recorder/logger-analyze power system stability by recording reclose sequences, power swing, and frequency oscillations
  • Trend recording-verify voltage regulation and balancing
  • Power quality monitor-voltage and frequency profiles, voltage dips and surges, loss of supply, harmonic content, flicker, voltage and current imbalance
  • Phasor Measurement Unit-synchronized phasor measurements, in accordance with IEEE C37.118-2005
  • Fault locator-calculates distance to fault based on configurable line model
  • Real time monitor-view analog, digital inputs, and computed values in near real time
  • Sequence of events recorder-1 msec or better resolution on digital contacts
  • 40 GB Solid State Disc

Specifications

Inputs

  • Number of Channels - 8, 16, 24, or 32 Analog, 16, 32, 48, 64, 80, 96, 112,128, 144 or 160 Digital
  • Voltage Inputs - 63.5 or 110 V RMS Nominal
  • Current Inputs - 1 A or 5 A RMS Nominal (thru Current Shunts/CICT’s)
  • Frequency Response - DC - 1/2 Sampling Rate (1/4 Sampling Rate for 384 Samples per Cycle only)
  • Accuracy - Better than 0.1 % of Full Scale
  • Digital Inputs - 24/48/125/250 Vdc Normally Open or Closed Wetted Contact

Recording (Transient)

  • Recording Resolution - 16 bits, 65536 Levels (15 plus sign)
  • Sample Rate - 384 Samples per Cycle, Optional 768 Samples/Cycle
  • Pre-fault Time - 2 to 600 Cycles
  • Post-fault Time - Fault Length will extend as Long as a Trigger Condition Exists. Min. is 8 to 100 Cycles
  • Safety Window - Number of ‘Clear’ Cycles that must occur at the End of the Recording: 0 to 16 Cycles
  • Maximum Record Length - Max. Size 1 to 60 sec. (This prevents Memory Filling with a Continuous Trigger)

Recording (Disturbance)

  • Sample Rate - 2 x Supply Frequency (100/120 Hz)
  • Pre-fault - 10 sec. to 10 min.
  • Post-fault Time - Fault Length will extend as long as a Trigger Point Condition Exists. Min. Value is 30 sec. to 5 min.
  • Maximum Record - Absolute Max.: 30 minutes
  • Computed Values  - Voltage and Current, Real Power, Reactive Power, Apparent Power, Power Factor, Total Harmonic Distortion and Frequency (x2), Positive, Negative and Zero Sequence, Voltage Imbalance

Recording (Disturbance Logging - Optional)

  • Sample Rate - 1/2 x Supply Frequency (25/30 Hz)
  • Recording Time - 2 Weeks

Recording (Trend)

  • Sampling Interval - 1 minute, or 10 minutes - Data can be Retrieved at up to a 60 minute Interval
  • Record Length - 52 weeks
  • Stored Parameters - Max., Min., and Average Voltage, Current, Frequency (2), Power, Flicker, Harmonics, and Imbalance. Digital Data in SER Format at User Defined Time Resolution

Triggering (Transient)

  • Analog Channels - Over/Under RMS Level, Rate-of-Change and THD. Positive, Zero and Negative Sequence Triggers, Over, Under and R-o-C Frequency Triggers, Differential Frequency
  • Digital Channels - Normal to Alarm State and Return to Normal State. Edge or Level Sensitive

Triggering (Disturbance)

  • Analog Channels - Under/Over Level of Fundamental and R-o-C, Frequency and ROCOF, Power and Frequency Oscillation, Imbalance and Impedance, Cross Trigger from Transient Recorder

System Timing

  • Time Source - Internal GPS Receiver with 1 PPS Output for Phasor Measurement, Optional IRIG-B
  • Accuracy - Normally better than ± 60 ns
  • Synchronization - 1 pulse per second on Optical Port. Any number of Systems can be Linked together

Communications

  • Serial Ports - Up to 4 x RS-232 Type
  • Default Setting - 57.6 kbaud, 8 bits, 1 stop, No Parity. Rates can be set up to 115 kbaud
  • Modem - Hayes Compatible Type Internal or External, Fax Compatible
  • Phone Line Sharing - External Unit to Share a Single Phone Line with a Station Phone
  • Network - 10Base2 (50 ohm coax and BNC), 10baseT, Fiber, Network Protocol: TCP/IP

Data Storage

  • Permanent Storage - 40GB Solid State Drive

Power Supply

  • Input Voltage Options - 100 to 300 Vdc, 85 to 264 Vac, (Optional 85 to 150 Vdc, 85 to 264 Vac)
  • Power Requirement - 60 VA (16 Channel), 70 VA (32 Channel)

Voltage Withstand

  • Isolation, Impulse Voltage, RFI and ESD per IEEE /IEC Standards

Enclosure - Cabinet

  • 6U TR-2508 and TR-2516
  • 8U TR-2508-D1, TR-2508-D2, TR-2516-D1, TR-2516-D2, TR-2524 and TR-2532
  • 9U TR-2508-D3, TR-2508-D4, TR-2516-D3, TR-2516-D4, TR-2524-D1, TR-2524-D2, TR-2532-D1, and TR-2532-D2

Environment

  • Operating Temperature - 14° F to 131° F (-10° C to 55° C)
  • Relative Humidity - 0 to 97 % Non-Condensing

Certifications

  • CE

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more