Yodify Product Library
Instantly add the Model 2010BR Oxygen Analyzer and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Since 2004 the Model 2010BR has been the unquestioned market leader, the industry-standard hazardous area trace oxygen analyzer. 

Over the years it has been continuously refined to the point that it now provides every feature you can possibly need – and many that you may not have thought of - in a compact, easily installed low-cost package. 

Many thousands of these analyzers are operating to specification in the harshest environments all over the country. 

Trace oxygen analyzers are essentially leak detectors.

AMI’s patented cell block allows the analyzer to be built with almost no possibility of internal leaking, with minimal volume and with front- panel sensor access. 

All sample handling components – the flow meter, needle valve and a four-way sample/span/off selection valve – are integrated into a solid metal block. 

Connections between them are drilled passages. 

The result is a highly reliable sample system with all necessary components provided, and a very fast “come-down” time – when a sensor is replaced, or calibrated on air with a 1 minute exposure (at 70° F), it takes about 15 minutes for it to come down to below 10 ppm.
Features
  • Display reads oxygen from 0.05 ppm up to 25.0% with no range changes
  • Analog output and alarms can be configured to operate over any of ten ranges from 0-10 ppm to 0-25% for best resolution
  • Field selectable Analog output - 1-5 V or 4-20 mA, isolated. CSA approved to meet Class 1 Div. 1 Group BCD with a flammable sample Complete sample
  • System built in to AMI’s patented cell block. Very rapid response time from air to low ppm levels. Easily replaceable sensor, no tools required

Specifications

Approvals & Certifications

  • CSA Class I, Div. 1, Groups B, C, D
  • UL

Enclosure, Body Material

  • Metallic

Measuring Range

  • 0 to 0.5 %

Power Requirement

  • 10-28 Vdc / 115 Vac, < 70 mA @ 12 Vdc Non- Heated, < 24 W @ 12 Vdc with Heated Option. Alternative 117 Vac Available

Pressure Range

  • Inlet Gas Pressure - psig: 0.5 to 150 (kPa: 3 to 1,034, bar: 0.03 to 10.34)

Range

  • 0 to 1 %
  • 0 to 1,000 ppm
  • 0 to 10 ppm
  • 0 to 10 %
  • 0 to 100 ppm
  • 0 to 25 %
  • 0 to 5 %
  • 0 to 50 ppm

Repeatability

  • ± 1 % of Range or ± 0.2 ppm of Oxygen, whichever is greater