Yodify Product Library
Instantly add the IR-640 Carbon Dioxide Sensor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
IR-640 Carbon Dioxide Sensor
Brand: Detcon IncDetcon Model IR-640 sensors are non-intrusive “Smart” sensors designed to detect and monitor Carbon Dioxide.
Available ranges of detection are 0-0.3%, 0-1%, 0-3%, and 0-5% by volume.
The sensor assembly consists of a miniature infrared optical sensor in a stainless steel housing that includes a splashguard with integral cal port, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.
1 - 8 of 8 Part Numbers
966-404520-001
- Junction Box - Aluminum
- Measuring Range - 1%
966-404520-003
- Junction Box - Aluminum
- Measuring Range - 3%
966-404520-005
- Junction Box - Aluminum
- Measuring Range - 5%
966-404520-0X3
- Junction Box - Aluminum
- Measuring Range - 0.3%
966-40542B-001
- Junction Box - 316 Stainless Steel
- Measuring Range - 1%
966-40542B-003
- Junction Box - 316 Stainless Steel
- Measuring Range - 3%
966-40542B-005
- Junction Box - 316 Stainless Steel
- Measuring Range - 5%
966-40542B-0X3
- Junction Box - 316 Stainless Steel
- Measuring Range - 0.3%
1 - 8 of 8 Part Numbers
Specifications
Brand
Accuracy
- ± 5 % of Full Scale
Approvals & Certifications
- CSA Class I, Div. 1, Groups B, C, D
- NRTL Class I, Div. 1, Groups B, C, D
Communication
- Modbus Via RS-485
Consumption
- < 3 W at 24 Vdc
Display
- Backlit LCD Display
Electrical Connectors
- Junction Box
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- Explosion-proof Class I, Div. 1, Groups B, C, D
- IP66
- NEMA 4X
Humidity
- 0 to 99 % Relative Humidity, Non-Condensing
Indication
- LED Indicator for FAULT & CAL Status
Input
- 22.5-28 Vdc
Materials of Construction
- 316 Stainless Steel - Junction Box
- Aluminum - Junction Box
Measuring Range
- 0 to 0.3 % by Volume
- 0 to 1 % by Volume
- 0 to 3 % by Volume
- 0 to 5 % by Volume
NPT Connection
- 3/4” NPT Female
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Output
- Linear 4-20 mA DC
Relay Output
- 3 Relays (Alarm 1, Alarm 2, & Fault)
Repeatability
- ± 5 % of Full Scale
Response Time
- T50 < 15 seconds
- T90 < 40 seconds
Sensor, Probe Type
- Non-Dispersive Infrared Optical (NDIR) - Sensor
Zero Offset
- < 0.05 % Per Year - Zero Drift