Q45 or 85 Peracetic Acid Transmitter

Brand: Analytical Technology Inc

As with any disinfection system, maintaining proper residual values is the key to effective pathogen control. 

To facilitate reliable chemical feed control, ATI has developed an on-line water quality monitor cable of providing real time measurement of low levels of PAA in solution. 

The Q45-85 Peracetic Acid Monitor uses a direct sensing polarographic probe. 

The probe is typically used in a flowcell, but a submersible sensor is also available. 

A permeable diffusion membrane isolates the sensing electrodes from the measured sample, providing long-term stability without electrode fouling problems. 

The measurement is selective for PAA and is not affected by changes in hydrogen peroxide concentration, which is always present in PAA solutions.
Features
  • Programmable range options from 0-2 PPM up to 0-200 PPM provide maximum application flexibility. AC Power Options:
  • Power options include 115/230 Vac. Analog Output Options:
  • Two isolated 4-20 mA outputs are standard. Default setting provides Analog outputs for PAA and temperature. PID Output:
  • Standard PID control function assignable to one Analog output. Relay Outputs:
  • Two SPDT relays are standard, with relay functions programmable for alarm, control, or trouble indication. Flexible Mounting:
  • NEMA 4X (IP-66) enclosure is suitable for wall, pipe, or panel mounting. Clear Display:
  • Back-lit large LCD display provides clear visibility in any lighting conditions. A scrolling second line on the display provides additional information and programming prompts.

Specifications

Display Range

  • 0-20.00, 0-200.0, 0-2000 ppm or mg/L

Accuracy

  • 0.5 % of selected range or 0.02 ppm

Repeatability

  • 0.3 % of selected range or 0.01 ppm

Sensitivity

  • 0.05 % of Selected Range

Linearity

  • 0.1 % of Selected Range

Temperature Drift

  • 0.1 % of Span/°C

Sensor Type

  • 2E Amperometric (Polarographic) Membraned Sensor

Temperature Input

  • Pt100 in Sensor for Temperature Compensation

Power

  • 2- Wire Unit: 17-30 Vdc, 25 mA Max.
  • Battery Unit: Two AA Alkaline Batteries
  • External DC: 5-17 Vdc, 10 mA Max.

Analog Outputs

  • 2-Wire Unit: Single 4-20 mA DC, 450 ohms Max.
  • Battery Unit: Two 0 - 2.5 Vdc, 50K ohms min.
  • External DC: Two 0-2.5 Vdc, 50K ohms Min.

Output Isolation

  • 600 V Galvanic Isolation

Enclosure

  • NEMA 4X (IP-66) Polycarbanate, V-0 flammability

Mounting Options

  • Wall or Pipe Mounting Bracket Supplied

Conduit Entries

  • Two PG-9 Cord Grips, 0.16 - 0.31" Diameter Cable

Ambient Temperature

  • Operating: -40° to + 60° C
  • Storage: -40° to + 70° C

Ambient Humidity

  • 0-95 %, Non-Condensing

Size

  • 4.4" H x 4.4" W x 3.5" D (111 x 111 x 90 mm)

Weight

  • 2-Wire or External DC Unit: 1 lb (0.45 Kg)
  • Battery Unit: 2 lb (0.9 Kg)

Certifications

  • CE marked to BS EN 61326-1:2006 Standard
  • UL and CSA General Purpose

PAA Sensor

  • Membrane-Covered Amperometric (Polarographic)

Sensor Materials

  • PVC & 316 Stainless Steel

Sensor Response Time

  • 90 % in 60 Seconds

Sensor Temperature Limits

  • 0-50° C

Sensor Pressure Limit

  • 0-50 psig

Sensor Cable

  • 25 ft (7.5 m) Standard

Sensor Flowcell

  • Clear Acrylic Constant-Head Overflow or Sealed Acrylic Flowcell

Sensor Sample Flow Rate

  • 7 - 15 GPH (0.5 - 1.0 LPM)

  • Egg Washing Systems
  • Wastewater Treatment
  • Ground Water Decontamination
  • Bleaching Systems
  • Oil & Gas Recovery Systems
  • Cooling Towers Cleaning