Yodify Product Library
Instantly add the EL-FLOW Base Mass Flow Controller and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

EL-FLOW Base Mass Flow Controller

Brand: Bronkhorst

The Mass Flow Controllers of the EL-FLOW Base series are standard and straightforward instruments. They provide accurate measurement, fast response and stable control in common gas flow applications.

EL-FLOW Base is an economical solution for installation in (OEM) systems e.g. in coating or welding applications. The instruments operate on the principle of thermal mass flow measurement in ranges starting from 0.2-10 mlₙ/min up to 4-200 lₙ/min air-equivalent.

They offer Analog I/O-signals as well as digital RS232 communication and/or Modbus-RTU as a standard feature. EL FLOW Base is a member of Bronkhorst’s most popular and field proven EL-FLOW series.
Features
  • Accurate mass flow measurement/control
  • Fast response, excellent repeatability
  • Virtually pressure and temperature independent
  • Cost effective solution
  • Analog I/O-signals: 0-5 (10) Vdc or 0(4)-20 mA
  • RS232 communication
  • Modbus-RTU or -ASCII
  • Control characteristics digitally configurable by user

1 - 12 of 24 Part Numbers
F-201AB-NNNA-AAD-0-K
F-201AB-NNNA-AAD-0-K
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…5 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201AB-NNNA-AAD-0-V
F-201AB-NNNA-AAD-0-V
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…5 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
F-201AB-NNNA-ABD-0-K
F-201AB-NNNA-ABD-0-K
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…10 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201AB-NNNA-ABD-0-V
F-201AB-NNNA-ABD-0-V
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…10 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
F-201AB-NNNA-AFD-0-K
F-201AB-NNNA-AFD-0-K
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…20 mA Sourcing
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201AB-NNNA-AFD-0-V
F-201AB-NNNA-AFD-0-V
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…20 mA Sourcing
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
F-201AB-NNNA-AGD-0-K
F-201AB-NNNA-AGD-0-K
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 4-20 mA Sourcing
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201AB-NNNA-AGD-0-V
F-201AB-NNNA-AGD-0-V
  • Base Model - Flow Rate - 0…20 mln/min / 0…70 ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 4-20 mA Sourcing
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
F-201CB-NNNA-AAD-0-K
F-201CB-NNNA-AAD-0-K
  • Base Model - Flow Rate - 0…10 Mln/min / 0…20 Ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…5 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201CB-NNNA-AAD-0-V
F-201CB-NNNA-AAD-0-V
  • Base Model - Flow Rate - 0…10 Mln/min / 0…20 Ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…5 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
F-201CB-NNNA-ABD-0-K
F-201CB-NNNA-ABD-0-K
  • Base Model - Flow Rate - 0…10 Mln/min / 0…20 Ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…10 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Kalrez
F-201CB-NNNA-ABD-0-V
F-201CB-NNNA-ABD-0-V
  • Base Model - Flow Rate - 0…10 Mln/min / 0…20 Ln/min
  • Nominal Range - Factory Selected
  • Communication - Analog + RS-232 or Modbus
  • Analog Output - 0…10 Vdc
  • Supply Voltage - +15…24 Vdc
  • Connections (In/Out) - None (Factory Standard)
  • Seals - Viton
1 - 12 of 24 Part Numbers

Specifications

Brand

Approvals & Certifications

  • EMC: EU Declaration

BSP Connection

  • 1/4” BSPP Female

Environmental Protection

  • IP40

Accuracy

  • ± 1 % Full Scale

Repeatabiliy

  • < 0,2 % Rd

Operating Pressure

  • 0…10 bar(g)
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more