SL - Self-Regulating Temptrace™ Bundles for Low Temperature Maintenance

Brand: Parker Hannifin

SL-Temptrace™ electric trace tubing bundles deliver freeze protection and provide low temperature maintenance for gases, liquids and other viscous materials in chemical processing and refinery applications.

Parflex SL-Self-Regulating Temptrace™ Bundles are designed to provide freeze protection and low temperature maintenance for gases, liquids or other viscous materials in chemical processing and refinery applications.

The tubing is thermally insulated with a non-hygroscopic inorganic fiberglass material and protected with a flexible, black, flame-resistant PVC jacket for added protection.

The thermal insulation allows for the transfer of fluids or gases up to 185°F (85°C) while maintaining an outer jacket surface temperature of 140°F (60°C), meeting NEC Personnel Protection Code 427.12.

Standard SL designs come with an internal tinned copper braid on the heating cable for grounding purposes and a TPR jacket over the heating cable to provide additional protection against many inorganic chemical solutions.

For order details, refer to our latest literature on the Product Support tab.
Features
  • Product is highly customizable – multiple options are available for tubing materials, tubing sizes, wall thicknesses, heating cable voltage and heat output, cover material and color
  • Constructed with a flexible, flame-resistant PVC jacket for added protection
  • Standard designs come with an internal copper braid on the heating cable for grounding purposes and a TPR jacket over the heating cable to provide additional protection against many inorganic chemical solutions

Specifications

Breaker (Amps)

  • 25 Amps

Circuit Length (feet)

  • 215 ft to 270 ft

Cover Color

  • Black is Standard. Other Cover Colors are available Upon Request. See How to Specify & Order for Details.

Cover Material

  • Flame Resistant - PVC, TPE, PE & PU, PU, TPR, LDPE, PVDF

Heat Output (Watts/Ft)

  • 3, 5, 8 or 10 Watts/ft

Maximum Internal Exposure Temperature (°C)

  • 85° C

Maximum Internal Exposure Temperature (°F)

  • 185° F

Maximum Working Temperature (°C)

  • 85° C

Maximum Working Temperature (°F)

  • 185° F

Minimum Bend Radius (inch)

  • 7" to 12"

Nominal Product O.D. (inch)

  • 1.21" to 1.99"

Number of Tubes

  • 1 - Multiple

Tube O.D. (inch)

  • 1/8" to 1", Metric Sizes Available from 2 mm to 16 mm

Tube Wall Thickness (inch)

  • .016" to .083", Metric Sizes Available from .89 mm to 2.5 mm

Tubing Material

  • Seamless Stainless Steel Typical 316/316L ASTM A269, Welded Stainless Steel Typical 316/316L ASTM A269 & Seamless Copper Typical 122 DHP ASTM B68/B75 are Standard. Additional Tubing Materials are available, See How to Specify & Order for Details.

Voltage (V)

  • 120 or 240 Vac

Weight (Lbs/Ft)

  • 0.33 to 1.11 lb/ft

  • Designed to provide Freeze Protection and Low Temperature Maintenance for Gases, Liquids or Other Viscous Materials
  • Chemical Processing and Refining