Yodify Product Library
Instantly add the Operator Station MT-638 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Operator Station MT-638
Brand: R. STAHL AGThe MT-638-DVI3 HMI series includes KVM systems for hazardous zones 2 and 22.
The systems are rugged, i.e. extremely robust: IP66, shock, vibration and seawater-proof and suitable for temperatures ranging from -40 to +65 °C. As an option, the 15" display with a resolution of 1024 x 768 pixels is also available as a sunlight-readable version.
The display and additional function keys are well-protected underneath a chemically hardened and non-glare glass screen.
Further options include a camera, a Bluetooth antenna and a projected capacitive touchscreen with multi-touch function.
Depending on the distance to be crossed, choose from the following types of data transmission technology: via copper cable up to 150 m, via multimode fibre optic up to 550 m or via single mode fibre optic up to 10 km.
Features- KVM System, 15" display, optional sunlight-readable 1200 cd/m²
- Rugged design: IP66, shock, vibration and seawater-proof, temperature range -40 °C to +65 °C
- Compact, lightweight HMI design < 18 kg / 40 lbs
1 - 1 of 1 Part Numbers
MT638A
KVM System, 15" display, optional sunlight-readable 1200 cd/m²
Rugged design: IP66, shock, vibration and seawater-proof, temperature range -40 °C to +65 °C
Compact, lightweight HMI design < 18 kg / 40 lbs
Ambient Conditions
- Ambient temperature operation - -10 °C … +65 °C
- Ambient temperature operation 1 - -40 °C … +65 °C with heater
- Cold start temperature - -10 °C or -40 °C
- Corrosion resistance - Salt water 5 % NaCl / +20 °C / 2 h 93 % r.H. / +40 °C / 168 h ISA-S71.04-1985, severity level G3
- Damp heat - +55 °C / 95 %
- Damp heat cyclic - +55 °C (±2 °C) ≥ 95 % Humidity location class B
- Heat dissipation - Via heat pipes and cooling fins
- Heater operation - Automatic
- Shock - 18 Shocks 25 g / 6 ms Axis X, Y, Z
- Storage temperature - -40 °C … +70 °C
- Temperature note 1 - The cold-start temperature depends on the "outdoor installation" (with / without heater).
- Temperature note 2 - Cold-start temperature: If the HMI device is switched on at temperatures below -10 °C, the electronics and the display will need a certain warm-up time before everything works smoothly and the display starts to be legible. Depending on how low the temperature is, this process may last up to 3 hours.
- Vibration sinus - 5 to 13.2 Hz: ±1 mm 13.2 to 100 Hz: ±0.7 g Change cycle 1 oct/min Axis X, Y, Z
- Vibration sinus 1 - 5 to 58 Hz: ±0.075 mm 58 to 500 Hz: ±1 g Change cycle 1 oct/min Axis X, Y, Z
- Vibration sinus 2 - 5 to 1000 Hz 5 g
Components
- Keyboard - optional, attached keyboard and pointing device (trackball, or joystick (Ex ia)) or desktop keyboard with 105 keys (Ex ia) and optical desktop mouse (Ex ia)
Display
- Backlight - LED Technology
- Backlight service life - 70 000 h at +25 °C
- Display brightness - TFT 450 cd/m² SR 1200 cd/m²
- Display contrast - TFT 500:1 SR 600:1
- Display dimensions - 4:3
- Display resolution - XGA
- Display size centimetres - 38
- Display size inch - 15
- Display version - TFT colour display or sunlight-readable display
- Display version 2 - 16.7 million colours
- Function keys - 8 of which 2 brightness keys
- Total pixels - 1024 x 768
- Touch screen - optional, projected, capacitive (PCAP), multi-touch
- Touch screen technology - Glass touch
Electrical Data
- Bluetooth - optional
- Connection compartment - Power supply direct in integrated Ex-e connection box
- Connections - Via plug-in screw terminals, green
- Data cable - CAT7 installation cable AWG23
- Data cable length - max. 150 m
- Ethernet / Data - 1x 100/1000Base-TX (Ex nA)
- Frequency range - 50 - 60 Hz
- Front camera - optional, 5 megapixel, in-built
- Further connections - 12 / 24 V DC output 2 x fan
- Interface Audio - 1 x Audio line out (Ex nA)
- Interface medium - CAT7 Data transmission
- Interface reader - 1 x reader / barcode reader interface (Ex i)
- Interface Serial - 1 x RS-232 / RS-422 / RS-485 (Ex nA)
- Interface USB - 3 x USB (Ex ia) 1 x USB (Ex nA)
- Language support - User menu: English
- Max. input voltage Um - 250 VAC
- Operating system - independent
- Optional interface 1 - Bluetooth
- Plug version USB - USB-A connector
- Power consumption AC 1 - 0.6 A at 230 VAC (0.8 A when heater is in use)
- Power consumption AC 2 - 1.1 A at 110 VAC (1.7 A when heater is in use)
- Power consumption DC - 4.6 A at 24 VDC (6.9 A when heater is in use)
- Protection fuse AC - 5 A
- Protection fuse DC - 12 A
- Rated operational power - typically 100 W / max. 150 W (typically 340 BTU / max. 510 BTU)
- Rated operational voltage AC - 230 V
- Rated operational voltage DC - 24 V
- Status LED - LEDs - on / off (green) - voltage applied to supply line / power supply OK (orange) - heater on (blue)
- Transfer technology - KVM-DVI3
- Voltage range AC - 100 - 240 V
- Voltage range DC - 20 - 30 V
- Wiring - Flexible conductors 0.2 to 2.5 mm² (AWG24 to AWG14) Rigid conductors 0.2 to 2.5 mm² (AWG24 to AWG14)
Explosion Protection
- Application range (divisions) - Class I, Zone 2 Class I, Division 2 Class II, Division 2 Class III
- Application range (zones) - 2 22
- Certification ATEX - BVS 14 ATEX E 134 X
- Certification CEC - FM 16 CA 0141 X
- Certification CNEX - CNEx17.2233X
- Certification EAC - TC RU C-DE.ME92.B.00843
- Certification IECEx - IECEx BVS 14.0116X
- Certification NEC - FM 16 US 0278 X
- Certifications - ATEX, IECEx, EAC, NEC, CEC, CNEX
- Dust explosion protection ATEX - II 3(1) D Ex tc [ia op is Da] IIIC T115°C Dc
- Dust explosion protection CEC - Zone 22, Ex tc [ia Da] IIIC T115°C Dc Class II, Div. 2 Groups E, F, G T4 Class III
- Dust explosion protection CNEX - Ex tc [ia op is Da] IIIC T115°C Dc
- Dust explosion protection EAC - Ex tb [ia op is Da] IIIC T115°C Dc X
- Dust explosion protection IECEx - Ex tc [ia op is Da] IIIC T115°C Dc
- Dust explosion protection NEC - Zone 22, AEx tc [ia op is Da] IIIC T115°C Dc Class II, Div. 2 Groups F, G T4 Class III
- Gas explosion protection ATEX - II 3(1) G Ex nA nR [ia op is Ga] IIC T4 Gc
- Gas explosion protection CEC - Ex nA nR [ia Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D, T4
- Gas explosion protection CNEX - Ex ec nR [ia op is Ga] IIC T4 Gc
- Gas explosion protection EAC - 2Ex nA nR [ia op is Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex ec nR [ia op is Ga] IIC T4 Gc
- Gas explosion protection NEC - Class I, Zone 2 AEx nA nR [ia op is Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D T4
General
- Functional Description - The MT-638-DVI3 HMI series includes KVM systems for hazardous zones 2 and 22. The systems are rugged, i.e. extremely robust: IP66, shock, vibration and seawater-proof and suitable for temperatures ranging from -40 to +65 °C. As an option, the 15" display with a resolution of 1024 x 768 pixels is also available as a sunlight-readable version. The display and additional function keys are well-protected underneath a chemically hardened and non-glare glass screen. Further options include a camera, a Bluetooth antenna and a projected capacitive touchscreen with multi-touch function. Data is transmitted via CAT7 copper cable up to 150 m.
- Highlights - KVM System, 15" display, optional sunlight-readable 1200 cd/m² Rugged design: IP66, shock, vibration and seawater-proof, temperature range -40 °C to +65 °C Compact, lightweight HMI design < 18 kg / 40 lbs Data transmission via CAT7 copper cable up to 150 m
- HMI type - Operator station
- Product description - 15" KVM systems
- Product Description - KVM Systems SERIES 600 Device platform SHARK
- Product Type - MT-638-DVI3-1TX
- Series - Product Series MT-638
- Technology - Remote HMI KVM
- WebCode - MT638A
Mechanical Data
- Cable gland cable diameter range (1) - M16 = 4 … 8 mm / M20 = 10 … 14 mm / M25 = 14 … 18 mm
- Cable gland number (1) - 3 x M16, 3 x M20, 2 x M25
- Cable gland number (2) - 3 x M16, 3 x M20
- Cable gland thread size (1) - M16 x 1.5 / M20 x 1.5 / M25 x 1.5
- Cable gland thread size (2) - M16 x 1.5 / M20 x 1.5
- Cable gland type (1) - HSK-MZ-Ex
- Cable gland type (2) - Screw plug
- Cable gland wrench size (1) - M16 = SW 19 / M20 = SW 22 / M25 = SW 30
- Cut-out - No panel mount
- Dimensions (WxHxD) (1) - 380 mm x 394 mm x 137 mm (+52 mm cable entries)
- Dimensions (WxHxD) (2) - 380 mm x 394 mm x 212 mm
- Enclosure / Design (1) - VESA 200 Standard
- Enclosure / Design (2) - VESA 200 Top Connect
- Ingress protection - IP66
- IP enclosure back - IP66
- IP enclosure front - IP66
- Material back - Seawater-resistant powder coated aluminum
- Material front - Seawater resistant and coated aluminium, hardened glass
- Mounting position - any
- Weight - 18 kg
Mounting / Installation
- Enclosure design - VESA 200 Standard, VESA 200 Top Connect
- Enclosure type - Rugged Panel Design (RP)
- Mounting option - Yoke, handle and feet, sun-shade, panel mounting (with xx8 Mounting-Kit)
- Mounting type - when switched on: a fixed device (stationary, non-portable equipment)
1 - 1 of 1 Part Numbers