Yodify Product Library
Instantly add the FSP Firestop Putty and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

FSP Firestop Putty

Brand: Nelson

Nelson Firestop Putty (FSP) is a completely premixed and ready-to-use firestop product that can be hand pressed into place forming an immediate fire seal. 

When exposed to fire the putty material forms a hard char that creates a formidable barrier to smoke and flame. 

FSP is a blend of organic and inorganic materials that is hand moldable. FSP is reusable when adding or changing penetrating items since the material remains pliable and does not set up.
Features
  • Easily installed, highly pliable and reusable.
  • Requires no special skills or tools for installation.
  • It inhibits the passage of smoke, and flame, through penetrations and joints. It is ideal for cable penetrations, where cable additions are common.
  • To ensure adequate adhesion, all surfaces should be clean and free of dust, grease, oil, loose materials, rust or other substances.
  • Apply the required depth of FSP over various backing materials. Ensure that it makes complete contact with the inside surface of the opening, as well as the surface of each penetrating item.
  • Actual installation should be in accordance with the appropriate Nelson™ application system drawing.
  • Up to 3 hour rating.
  • Smoke and gas tight; weather resistant.
  • Acoustically tested; reduces noise transmission.
  • Gray bars packed 10 per carton: 25.4 mm x 76.2 mm x 304.8 mm (1" x 3" x 12") gray bar, 0.59 liters (36 cubic inches).
  • Gray pads packed 20 per carton: 3.2 mm x 152.4 mm x 177.8 mm (1/8" x 6" x 7"), 6.4 mm x 152.4 mm x 177.8 mm (1/4" x 6" x 7") or 6.4 mm x 101.6 mm x 203.2 mm (1/4" x 4" x 8").
  • Gray pads packed in bulk: 9.07 kg (20 lb), 1.08 liters (432 cubic inches).

Specifications

Brand

Additional NEC / CEC Compliances

  • ASTM E-84, Flame Spread, Smoke Developed. ASTM E-90, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions & Elements. NFPA 70, Wall Opening Protective Materials

Application Temperature

  • +4° & +43° C (+40° & +110° F)

Consistency

  • 7.00 mm (Penetrometer)

Density

  • 0.049 lbs/cu. In

Dielectric Strength

  • > 356 V/mil

NEC/CEC Certifications & Compliances

  • Underwriters Laboratories Inc. UL 1479 & ASTM E-814, Test Method for through Stop Fire Penetrations. ANSI/UL 263, Fire Tests of Building Construction & Materials.

STC Rating

  • 54

Storage & Handling

  • It Should be Stored Indoors. Long Term Storage Temperature: +60° C (+140° F) Max.

Test Compliance

  • Underwriters Laboratories Inc., Fill, Void or Cavity Material (XHHW). Factory Mutual (FM), U.S. Coast Guard & ABS (American Bureau of Shipping). City of New York, NY, Department of Buildings (MEA 135-00-M, MEA 196-84-M Vol. 3)

Testing Data

  • For Specific Test Criteria, Refer to the UL Fire Resistance Directory
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more