Fluxus G608 CA Thermal Energy & Compressed Air Meter
Brand: FLEXIMFor Compressed Air and Thermal Energy metering in hazardous areas.
Portable flow measurement of Compressed Air and Thermal Energy in hazardous areas.
The FLUXUS G608 CA Energy is the ideal tool for carrying out complete energy efficiency tasks (e.g. according to DIN ISO 50001 standards) within hazardous areas (ATEX Zone 1/2 and FM Class I, Div.2 approval) by allowing the measurement of compressed air flow rates as well as the monitoring of thermal energy quantities and the flow rate determination of any kind of liquid or gaseous media with just one device.
It is engineered to survey whole compressed air infrastructures, balancing the facilities, measuring on nearly every individual leg, determining the efficiency of compressors and last, not least, quantify and localise leakages.
It measures at gas / compressed air filled pipes with an inner diameter of DN6 up to DN2100 and from 3 bar pressurization upwards (for plastic pipes measurements can be undertaken at atmospheric pressure and below) by applying FLEXIM's proven transit-time correlation technique.
Special ultrasonic Lamb and shear wave transducers are simply clamped onto the outside of the pipe, thus no cutting into the pipe or process interruption is required for installation - especially a benefit for facilities where pipes can't be depressurizes easily.
It also means, that the flow meter can never be a potential source for leakages itself - a problem that conventional flow meters technologies are often facing!
Moreover, as the G608 CA Energy flow meter is highly mobile and flexible, it can be used nearly anywhere - punctual measurements at the same spot every time are thus a thing of the past.
The FLUXUS G608 CA Energy not only offers the flow measurement of compressed air, but also the quantification of thermal energy streams at heating or cooling plants - thus being the ideal tool for tapping into energy saving potentials.
Its accuracy and reliability is unrivaled - not only because of the carefully matched and paired 4-Wire PT100/1000 temperature probes or the enthalpy curves that are programmed into the transmitter.
The FLUXUS G608 CA Energy flow meter offers maximum flexibility.
As all of FLEXIM's portable flow meters, the G608 CA Energy's ergonomic design offers simple handling and maximum ease of use. Its internal Li-Ion battery allows for up to 14 hours of autonomous measurement.
Algorithms such as the correction of pipe wall echoes and transducer positioning errors ensure reliable and accurate measurement even in the most demanding application conditions.
Specifications
Brand
Accuracy for Gas / Compressed Air Flow Measurement
- ± 1 to 3 % of Reading ± 0.01 m/s Depending on the Application ± 0.5 % of Reading ± 0.01 m/s Field Calibrated
Accuracy for Liquid Flow Measurement
- ± 1 % of Reading ± 0.01 m/sec Depending on the Application ± 0.5 % of Reading ± 0.01 m/sec Field Calibrated
Battery
- Li-Ion, 7.2 V / 4.5 Ah, > 14 Hours Operating Time
Degree of Protection
- NEMA 4X / IP65
Explosion Protection
- ATEX, IECEx Zone 2 (Transducers Zone 1), FM Class I, Div. 2
Flow Channels
- 2
Flow Velocity Range
- 0.03 to 75 ft/sec for Liquids 0.03 to > 100 ft/sec for Gases (Dependent on Pipe Size)
Inputs
- 4 x Temperature (Pt1000)
Media Temperature
- -40° to 390° F for Gas Flow Measurement -256° to 750° F for Liquid Flow Measuremen
Operating Pressure Range
- From Atmospheric Pressure Upwards for Plastic Pipesfrom 45 psi Upwards for Metal Pipesno Upper Pressure Limitation
Operating Temperature of the Transmitter
- -14° to +140° F
Pipe Diameter Range
- 1/4” to 63” for Gas Flow Measurement1/4” to 36 feet for Liquid Flow Measurement
Documentation
Brochure
- FLUXUS CA Compressed Air Flow Measurement Solutions Brochure DE pdf 1.9 MB
- FLUXUS CA Compressed Air Flow Measurement Solutions Brochure EN pdf 1.9 MB
- FLUXUS CA Compressed Air Flow Measurement Solutions Brochure US pdf 2.0 MB
- FLUXUS F G601 and F G608 Brochure DE pdf 2.6 MB
- FLUXUS F G601 and F G608 Brochure EN pdf 2.6 MB
- FLUXUS F G601 and F G608 Brochure ES pdf 2.6 MB
- FLUXUS F G601 and F G608 Brochure FR pdf 2.6 MB
- FLUXUS F G601 and F G608 Brochure NL pdf 2.5 MB
- FLUXUS F G601 and F G608 Brochure RU pdf 2.7 MB
- FLUXUS F G601 and F G608 Brochure US pdf 2.7 MB
Specifications
- FLUXUS G608 A2 Technical Specification DE pdf 771 KB
- FLUXUS G608 A2 Technical Specification EN pdf 808 KB
- FLUXUS G608 A2 Technical Specification ES pdf 818 KB
- FLUXUS G608 A2 Technical Specification FR pdf 814 KB
- FLUXUS G608 A2 Technical Specification NL pdf 769 KB
- FLUXUS G608 A2 Technical Specification RU pdf 3.6 MB
- FLUXUS G608 F2 Technical Specification EN pdf 800 KB
- FLUXUS G608 F2 Technical Specification US pdf 804 KB