Brand: WIKA Alexander Wiegand SE & Co. KGExtensive test cycles not only guarantee a permanent resistance and long service life in all commonly used oils and fuels, including aggressive crude oils and biofuels, but also in flowing and stagnant waters and in wastewater treatment applications.
Features- Suitable for measurements in contaminated and aggressive media
- An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a minimum maintenance effort
- Can be used in explosion-protected areas
- Developed for wireless applications
Specifications
Accuracy
- ≤ ± 0.5 % of Span
- ≤ ± 1 % of Span
Ambient Temperature Range
- -40° to 80° C (-40° to 176° F)
Approvals & Certifications
- China RoHS Conformity (SJ/T 11364-2014)
Approvals & Certifications
- ATEX
- CRN
- EMC
- EN
- Ex
- IEC
- IECEx
- RoHS
Cable Length
- 10 to 3,250 feet (3 to 1,000 metres)
Consumption
- Current Output: Max. 25 mA Per Output
- Voltage Output: Max. 5 mA
Electrical Connectors
- Cable Outlet
Environmental Protection
- IP68
Non-Linearity
- ≤ ± 0.25 % of Span
- ≤ ± 0.5 % of Span
Output
- 0.1-2.5 Vdc (3-Wire, Low Power) / 2 x 0.1-2.5 Vdc (3-Wire, Low Power)
- 4-20 mA, 2-Wire / 2 x 4-20 mA (2 x 2-Wire, Galvanically Isolated)
- 4-20 mA + HART (2-Wire)
Power Supply
- 12-30 Vdc (with Ex Approval) - Output Signal: 4-20 mA + HART (2-Wire)
- 12-36 Vdc - Output Signal: 4-20 mA + HART (2-Wire)
- 3.6-36 Vdc - Output Signal: 0.1-2.5 Vdc (3-Wire, Low Power) / 2 x 0.1-2.5 Vdc (3-Wire, Low Power)
- 8-36 Vdc - Output Signal: 4-20 mA, 2-Wire / 2 x 4-20 mA (2 x 2-Wire, Galvanically Isolated)
- 9-30 Vdc (with Ex Approval) - Output Signal: 4-20 mA, 2-Wire / 2 x 4-20 mA (2 x 2-Wire, Galvanically Isolated)
Pressure Range
- bar: 0 to 6
- Inches WC: 0 to 250
- kPa: 0 to 600
- psi: 0 to 100
Pressure Type
- Absolute
- Gauge
Repeatability
- Non-Repeatability ≤ 0.1 % of Span
- Non-Repeatability ≤ 0.2 % of Span (with Voltage Output & Cable Length > 100 M (325 Ft))
Storage Temperature
- -30° to 80° C (-22° to 176° F)
Temperature Range
- -40° to 80° C (-40° to 176° F)
Wetted Materials
- 316L Stainless Steel
- 318LN
- FEP
- FKM
- Hastelloy C-276
- PUR
- PVDF
- Level measurement in vessel and storage systems
- Overfilling and no-load operation monitoring
- Level measurement in rivers and lakes
- Deep well and groundwater monitoring
- Battery-operated level measuring systems